2012 newest portable CO2 detector
nFeatures
nFeatures
uDesign for real time monitoring room carbon dioxide
level
uNDIR infrared CO2 sensor inside with special Self Calibration System. It makes the CO2 measurement more accurate and more reliable in use.
uMore than 10 years lifetime of CO2 sensor
uTemperature and humidity monitoring
uThree-color (green/yellow/red) LCD backlit indicating ventilation optimal/moderate/poor based on the CO2 measurement
uTwo alarm ways: buzzer alarm and backlight
Colours switch
uProvide optional 1xrelay output to control a ventilator
uEasy touch button for operation
uHigh quality with the perfect appearance,
best choice for home and office
u220VAC or 24VAC/VDC power selectable; power adaptor available; desktop and wall mounting type available
uEU standard and CE-approval
nApplication
New G01-CO2 monitor/alarm is used to monitoring room CO2 level, as well as room temperature and humidity. It provides one on/off output to control a ventilator with four CO2 levels presetting. Especially it provides both buzzer alarm and three colors backlit switching alarm.
uHotel, exhibition hall, hospital, shop, restaurant, air port, train station, theater and other public places
uHouse, villa, office, meeting room, classroom and other rooms
uAll ventilation systems
nHousing and LCD
nSpecifications
Gas detected | Carbon Dioxide (CO2) |
Sensing element | Non-Dispersive Infrared Detector (NDIR) |
Accuracy@25℃(77℉) | ±50ppm + 3% of reading (during 0~2000ppm) |
Stability | <2% of FS over life of sensor (15 yr typical) |
Calibration interval | ABC Logic Self Calibration Algorithm |
NDIR life | 15 years |
Response Time | <2 minutes for 90% step change |
Signal update | Every 2 seconds |
Warm up time | 2 hours (first time) 2 minutes (operation) |
CO2 measuring range | 0~5,000ppm |
CO2 Display resolution | 1ppm |
Power supply | 100~240VAC or 10~24VAC/VDC selectable in the order |
Consumption | 3.5 W max. ; 2.5 W avg. |
Temperature sensor | NTC 5K |
Humidity sensor | HS series capacitive sensor |
Temperature measuring range | 0~50℃(32~122℉) |
Humidity measuring range | 0~99%RH |
Relay output (optional) | One relay output with rated switching current: 3A, resistance load |
Operation conditions | 0~50℃(32~122℉); 0~95%RH, non condensing |
Storage conditions | 10~50℃(14~140℉) 20~60%RH non condensing |
Weight | 200g |
Dimensions | 130mm(H)×85mm(W)×36.5mm(D) |
Installation | Desktop and wall mounting(65mm×65mm or 2"×4"wire box) |
Housing and IP class | PC/ABS fireproof plastic material, protection class: IP30 |
Standard | CE-Approval |
nModels Guide
Model | Name | Description | Power Supply | Type | |
G01-CO2-B320D | CO2, temperature and humidity monitor/alarm | Three-color backlit LCD, buzzer alarm | 100~240VAC | Wall mounting | |
G01-CO2-B320D-NR | CO2 and temperature monitor/alarm (no RH option) | Three-color backlit LCD, buzzer alarm | 100~240VAC | Wall mounting | |
G01-CO2-B331C | CO2, temperature and humidity monitor/alarm | Three-color backlit LCD, buzzer alarm | 18~24VAC/VDC with a DC socket. | Wall mounting | |
G01-CO2-B331C-NR | CO2 and temperature monitor/alarm (no RH option) | Three-color backlit LCD, buzzer alarm | 18~24VAC/VDC with a DC socket. | Wall mounting | |
G01-CO2-B340C | CO2, temperature and humidity monitor/controller | Three-color backlit LCD, buzzer alarm; 1 on/off output; touch-key for operation | 18~24VAC/VDC | Wall mounting | |
G01-CO2-B340C-NR | CO2 and temperature monitor/controller (no RH option) | Three-color backlit LCD, buzzer alarm; 1 on/off output; touch-key for operation | 18~24VAC/VDC | Wall mounting | |
G01-CO2-B340D | CO2, temperature and humidity monitor/controller | Three-color backlit LCD, buzzer alarm; 1 on/off output; touch-key for operation | 100~240VAC | Wall mounting | |
G01-CO2-B340D-NR | CO2 and temperature monitor/controller (no RH option) | Three-color backlit LCD, buzzer alarm; 1 on/off output; touch-key for operation | 100~240VAC | Wall mounting | |
Optional Accessories | |||||
870 | Power adaptor | Input:100~240VAC, Output: DC 24V/ 240mA | Just for G01-CO2-B331C or G01-CO2-B331C-NR | ||
922 | Desktop bracket | As be the desktop type | Just for G01-CO2-B331C or G01-CO2-B331C-NR | ||