The basic specifications: 230 / 400V AC, 50Hz / 60Hz, 0.8Pf , three phase four wires
Use: can be used for the open type and the soundproof type , automatic type
Output range | 6.5kw ----1000kw |
Noise level | Below 65/75db at 7m (soundproof type) |
Engine brand | Cummins ,perkins ,ricardo , detuz, weichai, jichai etc |
Engine type | Water cooling, 4 stroke, direct injection |
Alternator | Stamford , marathon , leroy somer, STC etc |
type | Brushless , insulation class: H |
Frequency | 3% |
Frequency at stable state | 0.5% |
Frequency deviation at instantaneous state | ≤+10% |
Frequency return time | ≤3s |
Voltage deviation at stable state | ≤±1% |
Voltage deviation at instantaneous state | ≤±20% |
Voltage return time | ≤4s |
Voltage modulation | ≤0.3% |
Starting system | Dc alternator |
Short circuit protection | MCCB air switch |
Cooling system | Water cooling |
Automatic alarm system | High water temperature |
Low oil pressure | |
Over load | |
Battery charging failure | |
Operating display | Unit voltage, tri-phase load current and frequency display |
Water temperature ,oil pressure display | |
Fuel level, fuel temperature display | |
Fuel tank | For 8 hours using |
2)THE SPECIFICATIONS OF THE ALTERNATOR:
The world first class alternator, brushless and self-excitation, it be can supply excitation in many cases:
· STAMFORD/ MARATHON/ LEROY SOMER
· Standard pitch winding can be inhibit currents interruption
· Insulation Class: H Protection class: H
· Frequency at stable state: ≤±1.0%
· Telephones interference: THF < 2%, TIF < 50
3) Control system:
a) Automatic alarm system: the unit has the ocus to-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
a) Automatic alarm system: the unit has the ocus to-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
4) Supply standard collocation:
a) Diesel engine with all accessories, 3 filter, electric systems
b) Alternator
c) Steel structure
d) Fan and water tank cooling system
e) Flange connector
f) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and Battery line
k) Set shock absorber
a) Diesel engine with all accessories, 3 filter, electric systems
b) Alternator
c) Steel structure
d) Fan and water tank cooling system
e) Flange connector
f) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and Battery line
k) Set shock absorber