Pioneer EKG312 applies a large LCD monitor to display 12 channels of ECG wave. It presents real-time clock, real-time measurement and ECG parameter. ECG312 is able to save 8 patients`ECG data and last up to at least 2 hours`working time with Li battery. USB and RS232 ensure the data transfer to PC.
Features
1. Simultaneously acquisition of 12-lead ECG data, IEC Class I, safety standard Leads: type CF
2. Manual: single channel or three
Auto I: standard three channel
Auto II: standard single channel plus rhythm lead
Auto III: Arrhythmia Analysis
Auto I: standard three channel
Auto II: standard single channel plus rhythm lead
Auto III: Arrhythmia Analysis
3. Measurement/interpretation and distinguish point printing function under auto mode operation
4. Filters: AC, HUM, DFT
5. Gain: 2.5,5,10,20 and Auto five levels
6. Real-time clock, real-time measurement and presenting of ECG parameter
7. Large LCD (240*320dots) display 12 channel ECG wave forms
8. Battery: high-efficiency lithium battery, at least 2 hours' working time
9. Function of heart rate detection and protection against pulse shock while pacemaker applied
10. Storage of 8 patients' ECG data
11. Power: 220V/110V ( + 10%), 50/60Hz selectable
12. USB interface and RS232 ensures convey of ECG data
13. Option: ECG Software For net-working capacity
Advantages
1. 12-lead, 3-channel EKG
2. LCD Display
3. 128 Patients' information Storage
4. USB Connection as option
5. RS232 PC Connection as standard Configuration
6. Upgradable for better configuration
7. Recording Paper:63mm*20ml 63mm*30m
8. Standard Accessories: Patient Cable(1 pc), Chest Electrodes(6 pcs), Thermal Paper(1pc), Rechargeable Battery (1pc)
9. Gross weight:4.5kg
10. Net weight:3.5kg
11. Unit size:300*230*61mm
12. Packing size:375*295*195mm
Specification
leads | Standard 12 leads |
Acquisition | Simultaneous 12 leads |
Resolution | 18bit/1000Hz |
Operating Mode | Manual Mode,3 Auto Modes (with measurement report) |
Filter | AC ,EMG Filter |
Drift filter | Anti-Drift System |
CMMR | >60dB |
>100dB(with AC filter) | |
Input Circuit | Floating, Protection circuit against Defibrillator effect |
Input Circuit Current | <=0.1uA |
Input Impedance | >50MQ |
Patient Current Leakage | <10uA |
Calibration Voltage | 1mV+-3% |
Time Constant | > 3.2 s |
Frequency Response | 0.05-150Hz |
Noise Level | <=15uVp-p |
Threshold | <=20uV |
Paper Speed | 25, 50mm/s (+-3%) |
Sensitivity | Auto,2.5,5, 10, 20 mm/mV |
Recorder | High resolution thermal printer |
Paper specification | 63mmx30m,roll |
LCD display | Display menu, operation status and 12 lead ECG waveform |
Safety level | IEC60601-1 class I , type CF |
Power Supply | AC: 220V/110V+-10%1; 50/60Hz+-1Hz; 30VA |
DC: 14.4V-2000mAH rechargeable lithium battery | |
Dimension | 300mmx230mmx61mm |