Problem and solution
Problem | Reason | Solution |
Connect the power supply, but the indicator does not light | PCB problem Indicator problem | Change or repair pcb Change indictor |
Light NO1 flash | Connection of sensors Sensors damaged | Check connection Change new sensors |
Light NO 2 flash | Sensor wiring short circuit Sensors damaged | Check connection Sensors damaged |
Control unit is work ,and in on status, but no moving | Voltage problem Inverter problem Mechanical parts jammed (above 3 problem ,inverter will show error flash | Check mechanical Change invert |
Unable to change setting numbers and NO2 light flash | Limilted by the model 0 | Change in model 0 and resetting |
Upper and down stoke change too big or out of control | Mechanical place changed | Re-adjust the senor place |
During move there are strange sounds and sometime the gun move unstable | Too loose of chain | Tight it and change new chain |
Maintenance
1. The chains need be checked and adding machine oil on time .Need tight the chain if the chain is too long1,chain need changed each year ,the chain type is 10A. Please note ,when you change the chain please make sure the chain mechanical position is not change.
2. Clean the wheel and metal tube on time ,if there are too much dust ,please clean it use the knife .Make the working condition clean it the best way.
3. Check if the controller is sealed ,if the seal is broken and please change the new one .Clean all the accessories in the controller with air ,after cleaning and please close it on time .Or the dust will come into the controller.
4. Clean and check the base on time ,clean the motor with air.
5. If the mechanical situation is changed ,please readjust the stand point ,or the moving will out of control .The method is :push the key ↑ or ↓,let the spray gun move to the middle of the working stroke ,then adjust the sensor on the bottom of the base ,when the data on the "m" indicated 500 and then the setting is finished.