Application
The Aobest 1.8/3kV Wind-resistant Flexible And Twisted Cable can be used in the middle of the wind turbine power generation equipment and fixed installation of the tower or other similar occasions.
Standard: TICW 1-2009 standard.
Operatingcharacteristics
1)Rated voltage U0/U:450/750V,0.6/1kV,1.8/3kV
2)Max. admissibleoperating temperature of the conductor:
450/750V cable:70°C;
0.6/1KV cable: 90°C;
1.8/3kV cable:90°C;
3)The min.bending radius: 6D(D is the cablediameter).
4)Min.ambient temperature:
Nominal:-25°C;
Cold Resistant:-40°C;
Cold Resistant type:-55°C
Type and Construction
Type | Rated voltage | Construction |
FDEF-25(-40) | 450/750V | Copper conductor EPR insulatedChloroprene rubber sheathed wind-resistant flexible and twisted (cold resistance) cable |
FDES-25(-40) | 450/750V | Copper conductor Thermoplasticelastomer sheath wind-resistant flexible and twisted (cold resistance)cable |
FDGG-40(-55) | 0.6/1Kv 1.8/3Kv | Copper conductor silicon rubberinsulated silicon rubber sheath wind-resistant and twisted (cold resistance)cable |
FDGU-40(-55) | 0.6/1Kv 1.8/3Kv | Copper conductor silicon rubberinsulated Polyurethane elastomer sheath wind-resistant and twisted (cold resistance) cable |
FDEU-40(-55) | 0.6/1Kv 1.8/3Kv | Copper conductor EPR rubber insulatedPolyurethane elastomer sheath wind-resistant and twisted (cold resistance)cable |
FDEG-40(-55) | 0.6/1Kv 1.8/3Kv | Copper conductor EPR insulated siliconrubber sheathed wind-resistant and twisted (cold resistance)cable |
FDEH-25(-40) | 0.6/1Kv 1.8/3Kv | Copper conductor EPR rubber insulatedchlorosulfonated polyethylene sheathed wind-resistant andtwisted (cold resistance) cable |
FDES-25(-40) | 0.6/1Kv 1.8/3Kv |
|
Dimensions of the 1.8/3kV Wind-resistant Flexible And Twisted Cable
Type | Rated voltage | No. of core | Mm2 Nom.cross-sectionalcore |
FDEF-25(-40) FDES-25(-40) FDGG-40(-55) FDGU-40(-55) FDEU-40(-55) FDEG-40(-55) FDEH-25(-55) FDES-25(-40) | 450/750V 0.6/1kV | 1 | 1.5-400 |
2 | 1-25 | ||
3 | 1-300 | ||
3+1 | 4-185 | ||
4 | 1-300 | ||
5 | 1-25 | ||
6-36 | 1.5-4 | ||
1.8/3kV | 1 | 10-400 | |
3 | 10-240 |
Working characteristics
Rated voltage | Section area of the conductormm2 | The insulation resistance when20°C (MΩ•km) | Insulated resistance when rated worktemperature (MΩ•km) |
450/750V 0.6/1kV | ≤35 | 150 | 0.15 |
50-150 | 100 | 0.10 | |
185-400 | 80 | 0.08 | |
1.8/3kV | ≤35 | 250 | 0.25 |
50-150 | 200 | 0.20 | |
185-400 | 150 | 0.15 |