Input voltage:110v-220v
Frequency:50-60Hz
Input power:50w
Output voltage:max.20v(peak-peak value)
Output current:max.0.7A
Pneumatic control voltage:24V DC
Work temperature range:-5degree - 40degree
Compressed air date:
Max.Input air pressure:10bar/145psi
Min input air pressure:6bar/87psi
Max water vapour content:1.3g/nm3
Powder hopper capacity:45L/55L
Powder spray gun
Input voltage :max.20v(peak-peak value)
Input current:max.0.7A
Output voltage:0-100KV
Polarity:negative
Output current:0-150uA
Powder yield:600g/min
Gun weight:550g
Connection table:5M
Machine weight:35kgs
powder coating Machines are including:
1. control unit 1set
2.powder spray gun 1pc
3.fluidized powder hipper 1set
4.powder pump 1set
5.trolley 1set
6.gun cable: 1pc
7.powder tube
8.wind pipe
9.ground wireTROUBLES
Problem | Cause | Measure |
High –voltage display does not operated even after powder is on and trigger is pulled | . Electric faulty-The electric line coming into CONTROL UNIT is not property connected . Faulty fuse and bad equipemnt on the part of external power source . .Faulty lamp. .Faulty printed circuit board(PCB) .Faulty line in GUN .Faulty in high-voltage generation part .Faulty trigger switch | . connect the power Replace Preplace Preplace Preplace Preplace Preplace Preplace |
The powder would not be fluidified | .The fluidzing air hose is not connected or compressed air is not input . Faulty fluidizing plate . Faulty operation of pressure reduction valve | .Connect after checking .Replace .Replace |
The gauge hands of CONVERYING AIR and DOSING AIR do not move during operation | .operation mistake: The power switch is not pressed .The trigger is not pulled .Faulty SOLENOID valve .Faulty PCB | . Turn on the power switch .Check while pulling the trigger . Replace |