Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request.
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/13/3 6/6 8.7/10 12/15 18/20 - 26/35
2nd class 1/13/3 6/6 8.7/10 12/15 18/20 - 26/35
Application:
These cables are most suitable for direct burial or for installation on traysor ducts,Where there is
a risk of mechanical damage, armoured cables shouldbe used.
a risk of mechanical damage, armoured cables shouldbe used.
Construction:(Example of YJV32 8.7/15kV)
Copper(aluminum)conductor or conductor screen
XLPE insulation or insulation screen
Color for core identification
Assembly/beding/armoured/outer sheath.
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 7095 120 150 185 240 300 400 500 630 800
Some common use models
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 7095 120 150 185 240 300 400 500 630 800
Some common use models
Type | Description | Application | |
Cu | Al | ||
YJV | YJLV | XLPE insulation PVC sheath power cable | To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bearmechanical force outside |
YJY | YJLY | XLPE insulation PE sheath power cable | |
YJV22 | YJLV22 | XLPE insulation, steel tape armor,PVC sheath power cable | To be laid underground, the cable could bear certain mechanical force, but itcouldn't bear great pulling force. |
YJV23 | YJLV23 | XLPE insulation, steel tape armor,PE sheath power cable | |
YJV62 | YJLV62 | XLPE insulation, have no the magnetism steel tape armor,PE sheath powercable | |
YJV32 | YJLV32 | XLPE insulation, thin steel-wirearmor,PVC sheath power cable | Be applicable to the well, water inside and fall in the bad soil, the cablecans bear the equal dint outside the machine with pull the dint . |
YJV72 | YJLV72 | XLPE insulation, have no the magnetism thick steel-wirearmor,PVC sheathpower cable | |
YJV42 | YJLV42 | XLPE insulation, thick steel-wirearmor,PVC sheath power cable | Be applicable to the well, underwater with the bottom of sea, the cable cansbear the bigger pressure with lead to pull thedint. |
| 1st class | 0.6/1kv | 1.8/3kv | 3.6/6kv | 6/10kv | 8.7/15kv | 12/20kv | 18/30kv | 21/35kv | |||
2nd class | 1/1kv | 3/3kv | 6/6kv | 8.7/10kv | 12/15kv | 18/20kv | - | 26/35kv | ||||
1 Core | Section area(mm2) | 1.5-800 | 25-800 | 25-800 | 25-800 | 35-800 | 50-800 | 50-800 | 50-800 | |||
2 Core | Section Area(mm2) | 1.5-185 | / | / | / | / | / | / | / | |||
3 Core | Section area(mm2) | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |||
4 Core | Section Area(mm2) | 2.5-400 | 25-400 | / | / | / | / | / | / | |||
5 Core | Section area(mm2) | 2.5-400 | 25-400 | / | / | / | / | / | / |
Note:many other types of the power cables can be produced. More info needed, pls contact me freely.