floor heating thermostat with two pole isolate switch

Payment Terms: T/T,L/C,D/A,D/P,WU
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: SASWELL 
  • easy heat thermostat: heating pad thermostat 
  • Model No.: SAS811FHL-0 
  • Place of Origin: Guangdong  
  • Min.Order: 100 Piece/Pieces
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 60000
  • Packing:50PCS/CTN.Carton dimensiones:48X33X36CM
  • Delivery Date: 15-25days after payment comfirmed
Details display of this product
SAS811FHL Non Programmable Mechnical Thermostat
Application:Heating system
Floor heatingTechnical data
1.Working voltage:200V~240V/50-60HZ
2.Accuracy of the temperature:±0.5°C
3.The temperature control range:10°C~50°C
4.Working environment temperature:0°C~+50°C
5.Storage environment temperature:-10°C~+60°C
6.Suitable area:Europe countries,UK,CN etc.
Mechnical thermostat Functional test specification
1,On the outside of the boot state, the knob is used to set temperature, set temperature range for 10 ~ 50 °C. Internal hidden potentiometer for the floor to set the upper/lower limit protection, setting range of 10 ~ 40 °C (only in Room thermostat with floor limitation or single floor mode effective)
2,The external temperature sensor fault alarm
Room thermostat with floor limitation or floor mode: When the external of temperature sensor short circuit or open circuit, the red light flashing, and stop the output.
3,Output logic
Closed thermostat broken power supply, stop heating.
The thermostat boot state:
1):Room mode,When the set temperature is greater than the room temperature heating startup,When the set temperature is less than the room temperature the heating stops;
2):Room thermostat with floor limitation mode,When floor temperature is greater than floor upper limit temperature protection stop heating;
Under normal working state,When the set temperature is greater than the room temperature heating startup,When the set temperature is less than the room temperature the heating stops;
3):Floor mode,When the set temperature is greater than the floor temperature heating startup,When the set temperature is less than the floor temperature heating stops;
4,Appears the clock signal, set temperature reduce 5°C
5,Light indicator:
red light:Heat output instructions
green light:The external timing signal input instructions(When there is signal input set temperature reduce 5°C)
Yellow light:The external timing signal input and heat output indicate at the same time
   The red light flashing:The external temperature error indication(Open circuit or short circuit)
Round type and suqare type option
                                                                           
Underfloor heating room Thermostat dimensiones:
Wiring diagram
Why you have to choose SASWELL to be your room thermostats supplier?
1)-ISO 9001:2008, SGS, VDE
2)-Monthly Production Capacity -- 60,000 pcs
3)-All goods examined before delivery by 8 STEPS QC PROCESS
4)-Prompt Reply Within 12 Hours
5)-4000 square meters work shop area
,7 years Gold Supplier certificated

Send message to this supplier
Ms. Jessie Ju
Tel: 86-755-61218391
Enter between 20 to 3,000 chatacters.
Contact Method
Saswell Control Co., Ltd.
3/F, Plant K, No. 8, East Region, Shangxue Science & Technology Park(Industry Zone), Xuexiang Commu, Shenzhen, Guangdong, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center