Photometric range - 4.0 - 4.0Abs, Double Beam, UV-Vis Spectrophotometer T90+

 

 

T90+ is a high performance double beam scanning spectrophotometer with a variable spectral bandwidth. The Czerny-Turner Monochromator with a holographic grating keeps stray light to a minimum and offers excellent optical resolution. The use of a photomultiplier tube as detector delivers exceptional sensitivity. The true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.


Features & Functions

  • Czerny-Turner Monochromator with high resolution holographic grating
  • High performance variable (0.1, 0.2, 0.5, 1.0, 2.0, 5.0nm) spectral bandwidth
  • Wavelength accuracy +0.3nm
  • Stepped Monchromator Drive
  • Excellent performance
  • Excellent baseline stability
  • High resolution
  • UV-Win software is supplied as standard for spectral, kinetic, photometric and quantitative analysis



Applications:

Pharmaceutical production and quality control
Bio-tech & life science
Environmental monitoring & control
Food & Beverage production and quality control
Agricultural monitoring
Clinical & forensic analysis
Geology & metallurgy
Gas & oil

 

 

Specifications:

 

Optical system

Double beam 

Scan speed

Selectable 

Wavelength range

190-900nm

Wavelength accuracy

+0.3nm

Wavelength reproducibility

≤0.1nm

Spectral bandwidth

0.1, 0.2, 0.5, 1.0, 2.0, 5.0nm

Photometric mode

Transmittance, Absorbance, Energy Concentration, all using UVWin software

Photometric range

-4.0-4.0Abs

Photometric accuracy

0.002A (0-0.5A), 0.004A (0.5-1A), 0.3%T (0-100%T)

Photometric reproducibility

0.001A(0-0.5A)

Photometric noise

0.0004A(500nm) 30min warm-up

Baseline flatness

0.001A(200-850nm)

Baseline stability

0.0008A/h (500nm, 0Abs), 2hr warm-up

Stray light

≤0.01%T(220nm NaI, 340nm NaNO2)

Standard functionality

No stand alone function

Cell holder

Fixed position sample and reference

Detector 

Photo

Send message to this supplier
Ms. April Cao
Tel: 86-10-69910653
Enter between 20 to 3,000 chatacters.
Contact Method
PG Instruments company Limited
No.3 Pingsan Road, Beijing, China (Mainland)
Related Products
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!