  • Model No.: KFD2-SR2-EX2.W 
  • Place of Origin: Shanghai  
  • Min.Order: 1 Piece/Pieces
  • Means of Transport: Air
Supply Capacity
  • Production Capacity: /
  • Packing:/
  • Delivery Date: /

KFD2-SR2-EX2.W : KFD2SR2EX2W Specification

Alternative Part Number: 

132960

Manufacturer: Pepperl + Fuchs

Pricing Unit: Each

Weight: 0.160 kg(each)

Tariff code: 85389099


KFD2-SR2-EX2.W

132960

Features

  • 2-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Dry contact or NAMUR inputs

  • Relay contact output

  • Line fault detection (LFD)

  • Reversible mode of operation

  • Up to SIL2 acc. to IEC 61508

  • Your benefits

    This isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.

    The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The normal output state can be reversed using switches S1 and S2. Switch S3 is used to enable or disable line fault detection of the field circuit.

    During an error condition, the relays revert to their deenergized state and the LEDs indicate the fault according to NAMUR NE44.

    A unique collective error messaging feature is available when used with the Power Rail system.

    Technical Data
    General Specifications
    Signal typeDigital Input
    Supply
    ConnectionPower Rail or terminals 14+, 15-
    Rated voltage20 ... 30 V DC
    Ripple≤ 10 %
    Rated current≤ 50 mA
    Power loss1 W
    Power consumption< 1.3 W
    Input
    Connectionterminals 1+, 2+, 3-; 4+, 5+, 6-
    Rated valuesacc. to EN 60947-5-6 (NAMUR)
    Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
    Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
    Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I > 6 mA
    Pulse/Pause ratio≥ 20 ms / ≥ 20 ms
    Output
    Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
    Output I, IIsignal, relay
    Minimum switch current2 mA / 24 V DC
    Energized/De-energized delayapprox. 20 ms / approx. 20 ms
    Mechanical life107 switching cycles
    Transfer characteristics
    Switching frequency≤ 10 Hz
    Electrical isolation
    Output/power supplyreinforced insulation according to IEC 61140, rated insulation voltage 300 Veff
    Output/Outputreinforced insulation according to IEC 61140, rated insulation voltage 300 Veff
    Directive conformity
    Electromagnetic compatibility
    Directive 2004/108/ECEN 61326-1:2006
    Low voltage
    Directive 2006/95/ECEN 50178:1997
    Conformity
    Electromagnetic compatibilityNE 21
    Protection degreeIEC 60529
    Protection against electric shockIEC 61140
    Ambient conditions
    Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
    Mechanical specifications
    Protection degreeIP20
    Massapprox. 150 g
    Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 in) , housing type B2
    Data for application in connection with Ex-areas
    EC-Type Examination CertificatePTB 00 ATEX 2080 , for additional certificates see www.pepperl-fuchs.com
    Group, category, type of protectionEx II (1) G [Ex ia] IIC, II (1) D [Ex ia] IIIC
    Input[Ex ia] IIC, [Ex ia] IIIC
    Voltage Uo10.5 V
    Current Io13 mA
    Power Po34 mW (linear characteristic)
    Supply
    Maximum safe voltage Um253 V AC / 125 V DC (Attention! Um is no rated voltage.)
    Output
    Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
    Maximum safe voltage Um253 V AC (Attention! The rated voltage can be lower.)
    Statement of conformityPepperl+Fuchs
    Group, category, type of protectionEx II (3)G [Ex ic] IIC; [Ex nL] IIC
    Input[Ex ic] IIC; [Ex nL] IIC
    Voltage Uo10.5 V
    Current Io13 mA
    Power Po34 mW (linear characteristic)
    Output
    Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
    Statement of conformityTÜV 99 ATEX 1493 X , observe statement of conformity
    Group, category, type of protection, temperature classEx II 3G Ex nA nC IIC T4
    Output
    Contact loading50 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
    Electrical isolation
    Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
    Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
    Directive conformity
    Directive 94/9/ECEN 60079-0:2009, EN 60079-11:2007 , EN 61241-11:2006 , EN 60079-0:2006, EN 60079-15:2005
    International approvals
    FM approval
    Control drawing116-0035
    CSA approval
    Control drawing116-0047
    IECEx approvalIECEx PTB 11.0034
    Approved for[Ex ia] IIC , [Ex ia] IIIC , [Ex ia] I


    KFD2-SR2-EX2.W P+F TRANSFORMER ISOLATED AMPLIFIER 



Send message to this supplier
Ms. Amanda Jiang
Tel: 86-21-64837823
Mobile: +86-13636308629
Enter between 20 to 3,000 chatacters.
Contact Method
KEM Controls Corporation Shanghai Office
1415#, Automation Instrument Building, No.103, Caobao Road, Shanghai, China (Mainland)
Fax: 86-21-64827259
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center