Company Info
Perlong Medical was established in 1993, Nanjing, China. We are a manufacturer specializing in R&D, manufacturing and marketing various kinds of medical equipments. Perlong owns nearly 11 subsidiaries and thousands of employees. In the past 18 years, Perlong Medical rooted with the spirit of "development, innovation, pragmatism and consolidation", and dedicated to attract talented people from the communities. Now, Perlong has grown up to be a mature and perfect medical company with a rapid speed... view more
Company Profile
Year Company Registered:
1993-05-04
Annual Sales Amount:
US$10 – 50 Million
Total No. of Staff:
501 – 1000 People
No. of R&D Staff:
51 – 60 People
No. of Engineers:
11 – 20 People
Export Ratio:
51% – 60%
OEM Services Provided:
YES
Payment Terms:
T/T, L/C, D/A, D/P
Business Type:
Manufacturer
Quality Certificate:
GS, CE
Main Export Markets:
North America, Western Europe, Eastern Europe, South America, Southeast Asia, Eastern Asia, Mid East, Oceania, Africa
Competitive Advantage:
Perlong Medical's main product line including X-ray Equipment & Related Instrument, Clinical Laboratory Equipment, Hematology Analyzer, Clinical Diagnosis Reagents, Hematology Reagents, Fast Diagnosis Products , etc.
Basic Info.
Brand Name:perlong
Place of Origin: Jiangsu
Min.Order: 1 Set/Sets
Means of Transport:Ocean
Supply Capacity
Production Capacity:100
Packing:wooden
Delivery Date:10
Specifications of C-arm System
1. Fluoroscopic Capacity Max rated capacity : Tube Current 4mA, Tube Voltage 110kV Automatic Fluoroscopy : Tube Voltage:40kV~110kV Adjust Automatically Tube Current : 0.3mA~4mA set manually
Features of C-arm System
1,With a compact appearance, and easy to operate; 2,Clinical Video system with high performance,8 images storage volume, and two 14"high-resolution monitors; 3,Automatically track fluoroscopy to make the image brightness and clearness optimum;
4,Automatically store the last image of fluoroscopy to advantage diagnosis;
5,With a high-quality knockdown X-ray generator to reduce radiation
Automatic collimation according to examination selected, can be overridden manually
Optical centering indication for positioning and side beam for central alignment of X-ray beam with detector assembly
Receptacle channels(s)/track(s) for insertion of external filters. A full set of dedicated filters, with filter holder for attachment to the collimator, has to be provided for exposure compensation for various anatomical regions such as skull , shoulder, spine and chest etc
A built-in electronic or mechanical measuring device for measurement of SID is incorporated
Provision of dose reduction filters , which are operator selectable or automatic for filtering of low energy radiation