IEC Three Phase Electromechanical Energy Meter Four wire

The DT86 three-phase fore-wire meter is designed to meet the latest IEC62053-21,IEC62052-11 standards for measuring active energy in three-phase four-wire alternating current power grids. Connection is direct or by instrument transformers.. It has an average service life(MTTF)of 20 years and maximum overload capacity of 600%Ib.

Terminal block

The terminal block is molded of heat-and flame-resistant Bakelite . It is fixed in the extended meter base. The voltage test link can be located inside or outside of the meter case.

Driving element

The driving element consists of a voltage element and a current element, both of which are fixed on the aluminum alloy frame. It has a load curve compensation device and inductive load adjustment mechanism.

Register Cyclometer single, unidirectional, Jumping

Technical data:

 

1

Meter type

DT86

2

Applicable Standards

IEC62053-21 sw IEC62052-11

3

Accuracy class

(according to IEC 60521)

Transformer

operated: Class 1

Direct connected:

Class2

 

4

Average service life (MTTF)

20 years

5

Basic current (lb)

1.5 3 5 5 10 15 20 30

6

Maximum current (lmax)

6 6 10 20 40 60 80 100??

7

Rating current of transformer

5A Direct connection

8

Reference voltage Un

3×57.7/100V,3×220/380V

3×230/400V,3×240/415V

9

Reference frequency fn

50Hz,60Hz

10

Power losses in voltage circuit at? 50Hz Un

1.0W/4.5VA

11

Power losses in current circuit at? 50Hz Un Ib

<0.5VA

12

Non-running with no-load

0.8~1.1Un

13

Starting current

0.4%Ib 0.5%Ib

14

Mean temperature coefficient

From 0.1Ib to Imax at unity PF

From 0.2Ib to Imax at unity 0.5 lagging

<0.08%/?

Send message to this supplier
Mr. Laurence Xu
Tel: 86-571-56660399
Enter between 20 to 3,000 chatacters.
Contact Method
xili watthour meter manufacture co.,ltd
No.11,Zhuantang Economic Park of Science & technology, Hangzhou, Zhejiang, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!