Copper Bare Aluminium Conductor With XLPE Sheath 6Awg ~ 266Awg 0.6 / 1KV

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

 

Copper Bare Aluminium Conductor With XLPE Sheath 6Awg ~  266Awg 0.6 / 1KV

 

 

Quick Detail:

 

Copper Bare Conductor with XLPE Sheath 

1.Low Voltage Copper Conductor

2.Black XLPE Outer sheath

3.Single Core 

 

 

 

Description:

 

1. Copper Bare Conductor with XLPE Sheath
 
2. Construction of ABC Cable
 
Conductors are aluminum alloy 1350H19, 6201181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).
 
3. Standards of ABC Cable
 

· ASTM B-230 - Aluminum 1350-H19 Wire for Electrical Purposes

· ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).

· ASTM B-1248 - Polyethylene Plastics Molding and Extrusion Materials.

· ASTM C-8.35 - Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.

· ICEAS-61-402

· NEMA PUB NO. WC 5-1973 - Standards Publication Thermoplastic insulated Wire and Cable 

  for the Transmission and Distribution of Electrical Energy.

 



Notes

 

· The code words as given apply to conventional polyethylene line wire.

· For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.

· Ampacity ratings based on 75oC conductor temperature, 25oC ambient temperature elevation sea level. 

  Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -375oC-    Cm2/Watt-CM. Wind speed 2ft/sec in sun.

· To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition. 

Item

Size
AWG or MCM

 

 

 

Insulation
Thickness
(mils)

 

Outside
Diameter

Rated
Breaking
Strength

Weight
Per
MFT
XLP

Weight
Per
MFT
POLY

Ampacity
XLP

Walnut

6

 

30 mls

 

.258 Inches

1131 Lbs

49 Lbs

47 Lbs

105 Amps

Butternut

4

 

30 mls

 

.303 Inches

1170 Lbs

71.8 Lbs

70.0 Lbs

135 Amps

Hickory

4

 


Send message to this supplier
Mr. Bruce Huang
Tel: 86-755-23154925
Enter between 20 to 3,000 chatacters.
Contact Method
China CCTV Coaxial Cable Online Market
Building B,ShenChangGang Science Park, Shenzhen, Guangdong, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!