Adjustable Veterinary Infusion Pump With Button Operation History Records

 

Product advantages

 

  • Infusion Modes: Rate Mode, Time Mode, Drip Mode & Body Weight Mode.
  • 4.3 inches colorful LCD screen.  
  • Button Operation history records.
  • Time and calendar display. 
  • Bolus & KVO function. 
  • Multi-language selection: English, Spanish, Russian etc.

 

Technical parameters

 

 

Bolus rate   

 

100~1000ml/h 

Applicable infusion sets

All brands of standard infusion sets    

Injection accuracy

±3% 

Infusion rate range 

1~2000ml/h 

Infusion increment 

0.1ml/h   

Rate mode 

1~2000ml/h

Selectable modes 

Rate mode, Drip mode,Time mode,  Body weight mode 

KVO rate

Adjustable, 1ml/h~5.0ml/h  

Time mode

Volume limit: 0.1~9999.9ml 

Time: 1~6000 minutes

Panel instructions

1, Infusion rate  2, Infusion preset volume  3,Accumulated infusion volume  4, Battery capacity   5, Battery charging indication  6,AC power supply connection indication  7,Over 8, OCCL. Alarm   9, Air   10, Bed    11,Pressure Value   12, Flow rate , etc.

 

Battery 

 

Rechargeable lithium polymer battery 7.4V, 3000mA, working for 4 hours(25ml/h) after being fully charged 

Body weight mode 

Weight: 0.1~300kg         Volume limit: 0.1~999.9ml 

Drug limit: 0.1~999.9mg  Dose:0.1~9999.9mg

Unit: mg/kg/h, ug/kg/min 

Accumulated volume 

0.1~9999.9ml  

Preset range  

0.1~9999.9ml 

Power supply 

AC100240V   50/60HZ 

Classification 

Class II, type BF

Occlusion value 

39.2kPa~137.2kPa, adjustable, pressure show on the graphic 

Alarm function  

Air, over, OCCLU, out of battery, low battery, CPU communication error, drop error, specification error,  no operation remind, door open, no AC power supply, installation error.

Electrical safety 

Meet the requirements of EN60601-1:1990+A1:1993+A2:1995

Storage condition 

Environment temperature: -20+55, air pressure (50106)kPa,relative humidity95%

Max power consumption 

25VA 

EMC 

Meet the requirements of IEC60601-1-2(2007 version)  

Operation condition 

Environment temperature: 5+40, air pressure (86106) kPa,  relative humidity80%  

Overall maximum size

125*140*205mm (Length*Width*Height)

Gross weight 

2.8kg   

 

 

Vet infusion pump 

 


Send message to this supplier
Mr. Luo
Tel: 86-20-86008946
Enter between 20 to 3,000 chatacters.
Contact Method
Shenzhen HAD Trading Co., Ltd.
3/F,Building 5,Nanshan Yungu Innovation Industrial Park, Guangzhou, Guangdong, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center