SWA / Steel Wire Armored Electrical Cable 100KV High Voltage Power Cable

Specifications

Steel Wire Armored Electrical Cable
1.Cable Voltage Max 800 KV
2.with"CCC" "ISO9001" "TLC" "CE"
3.Good After-Service

 

Electrical Cable :

Model No : YJV32 500KV

XLPE-insulated cable for rated voltage 66kV and 500KV

Executive Standards :

---XLPE-insulated power cables for rated voltage 110kV conform to GB/T11017-2002 ,which is equal to  IEC 60840:1999 Rated voltage 30kv to 150kv .

 

--XLPE-insulated power cables for rated voltage 220kV Voltage 220kV should perform to  GB/T 18890-2002,which is equal to IEC 62067:2001.Rated voltage 150kv to 500kv.

 

---XLPE-insulated power cables for rated voltage 500kV should perform to GB/T 22078-2008,which is equal to IEC 62067:2006 Rated voltage 150kv to 500kv .

 

---XLPE-insulated power cables for rated voltage 66kV should perform The Test Methods and Requirements of Extruded

 

Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999.

 

Main Performance :

  1. The rated voltage U0/U of cables:38/66kV, 48/66kV, max. voltage Um=72.5kV;

                                   64/110kV, max. voltage Um=126kV;

                                   127/220kV, max voltage Um=252kV;

                                   290/500kV, max voltage Um=550kV;

 

    2. permissible long-term working temperature of cable conductor:90°C;

 

    3. When the cable confronts short circuit within 5 seconds, the highest temperature of conductor        should not exceed 250°C.

  

When there exits line joints, the temperature of tin soldering ones should not exceed 120°C, the temperature of crimping ones should

not exceed 150°C, and the temperature of electric or gas welding should not exceed 250°C;

 

    4. When laying, the permissible bending radius should exceed 25 times of the out diameter of the cables.After laying, the permissible bending radius should exceed 23 times of the out diameter of the cables.

 

a.   When laying, ambient temperature≥0°C(when the cable has to be laid under the ambient temperature below 0°C,it is necessary to preheat the cable above 0°C)

 

b.  When laying, the cable is not limited by disparity with the satisfaction of mechanical pressure, but it is not permissible to lay the cable in the iron pipe, nor the circular iron materials around fixed cables.

 

The type, name, and suitable areas :

 Type

Description

 

Suitable for

 

Copper-conductor

 

AL-conductor