3 Pole MCCB Under Voltage Trip Circuit Breaker 250A High Performance

 

 

UKM30L Series Earth Leakage Circuit Breaker is developed with hi-tech in 1990S with completed protection functions, high performance, smart dimension which is the ideal replacements for the olds.

 

 

Description:

 

UKM30L series earth leakage circuit breaker are one of the new type earth leakage breakers which have been developed by the company using international advanced design and manufacturing technology. Suitable for a line of AC50Hz/60Hz, rated voltage up to 400V, rated current16A to 630A. And is acted as infrequent changeover of circuit or infrequent starting of motor. The breaker has overload, short-circuit and under-voltage protective function, which can protect the circuit and the power equipment against damage, meanwhile, it can provide protection to these fire dangers that caused by these long-time existed grounding fault that can not be detected by the over-current protection.

 

 

Specifications:

 

Frame rated current 100 250 400
Model UKM30L-100S UKM30L-250S UKM30L-400S
Ratedcurrent In(A) 16,25,32,40,50,63,75,100 100,125,150,175,200,225,250 250,300,350,400
Poles 3  4 3  4 3  4
Ratedvoltage Ui(V) AC690.50HZ AC690.50HZ AC690.50HZ
Ratedvoltage Ue(V) AC400.50HZ AC400.50HZ AC400.50HZ
Rated limit short/service breaking capitily Icu/Ics(KA) 50/25 50/25 50/25
Rated Actuation residual current 30,100,300, 500mA 30,100,300,500mA 30,100,300,500mA
Ratedresidual non-operattion current 1/2In 1/2In 1/2In
Rated residual short-circuit making & breaking capacity 1/4Icu 1/4Icu 1/4Icu
Operation charateristic (times) ON / OFF 1500 / 8500 1000 / 7000 500 / 4000

 

 

 

The Earth Leakage Circuit Breaker can operate at the following working conditions:

 

A. Ambient air temperature no more than +40º C and no less than -5º C

B. Altitude no more than 2000m

C. The relative air humidity is no more than 50% in the max. Temperature: +40º C. The higher relative humidity is allowable at the lower temperature. The min. Monthly means at the most moist month be no more than +25º C. The max. Monthly relative humidity at the most moist month be no more than 90%.

D. Pollution degree: Grade III. There is no explosion factor, corrosive metal and the gas destroying the insulation and the electric dust full of the ambient atmosphere.

E. Installation type: III

F. The terminals of" 1, 3, 5, N1" is to connect to the power supply and the terminals of"2, 4, 6, N2"s to connect to the negative load.

 

 

Overcurrent Protection Curve:

 

 


Send message to this supplier
Mr. Michael Deng
Tel: 86-571-62865157
Enter between 20 to 3,000 chatacters.
Contact Method
Zhejiang KRIPAL Electric Company
Daqiao Industrial Zone, Baixiang Town,Yueqing, Hangzhou, Zhejiang, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center