0.459kg RS232 RFID GPS Tracker Device Cutting Off Power Alarm
Performance Parameters:
Content |
Specs. |
Dim. |
95*75*25mm |
Weight |
0.459kg |
Network |
GSM/GPRS/WCDMA |
Band |
900/1800/1900MHz or 850/900/1800/1900MHz |
GPS chip |
U-blox |
GPS sensitivity |
-159dBm |
GPS accuracy |
5 m |
Time To First Fix |
Reacquisition 0.1s Cold status 45s Warm status 35s Hot status 1s |
Work Voltage |
DC 9V36V |
Battery |
Chargeable changeable 3.7V / 600MAh Li-ion battery |
Standby work current |
< 30mA |
Storage Temp. |
-40°C to +85°C |
Operation Temp. |
-20°C to +70°C |
Humidity |
5%--95% non-condensing |
Functional features:
- Geo-fence: Set up a geo-fence for the device to restrict its movements within a district. The device will send the message to all authorized numbers when it breaches the district.
- Restart the device: send SMS to resume the default of device.
- Auto Track: You can set up auto track by SMS or on-line positioning platform.
- Mileage statistics; ACC checking; cutting off power and alarm.
- Compatible with the original anti-theft alarm: It will send SMS alarm after the original anti-theft alarm warning.
- Modify the IP and Port of Communication Protocol for different on-line positioning platfor.
- fuel sensor ,temperature sensor and other sensor is optional .
- camera , lcd display, led display is optional
- GPS locating and tracking; Remote monitoring;
- SOS function;
- Romote controlling of oil and circuit;
- Blackouts alarm, Compatible with the original car alarms;
- Locating through phone message
- Acc checking;
- Moving and Speeding alarm;
- Mileage statistics and Geo-fence function;
- Cam supporting,oil testing;
- Can be equipped with the netmeeting handet and dispatching screen,supporting dispatching and two-way audio;
- also can be worked with camera;
- With support of temperature sensor(optional);
- With support of fuel sensor(optional);
- With support of speed sensor(optional);
Detail Pictures:
1Initialization
Send “begin + password” in SMS to the unit, it will reply “begin ok” and initialize all the settings. (Default password: 123456)
2. Add authorized number
Send SMS “admin123456 13612345678”. "admin" as instruction, "123456" as password, "13612345678" as authorized number. It will reply “admin ok!”.
3. Delete authorized number
Send SMS “noadmin123456 13612345678”. "noadmin" as instruction, "123456" as password, "13612345678" as deleted number. It will reply “noadmin ok!”.
4. Change the Password
Send SMS: “password + old password + space + new password” to change the password. For example: Send SMS “Password123456 138138”. "password" as instruction, "123456"as old password, "138138" as new password. Password must be six digits. Tracker’s initial password is 123456.
5. Resume the initial password
If you forget your password, you can resume the initial password 123456.
Send “resumepassword” to the tracker, the tracker will resume the initial password. If there is no authorized numbers, all numbers can resume initial password. If there is already authorized numbers, only the authorized numbers can resume initial password.
6. Control Oil
Send SMS “stopoil+password” to control oil. For example send SMS: stopoil123456
"stopoil" as instruction, "123456"as password.
To supply the oil again, send SMS “supplyoil+password” to the unit. For example, send SMS “Supplyoil123456” to the tracker. "Supplyoil" as instruction, "123456" as the password.
7. Control Circuit
Send SMS “stopelec+password” to control circuit. For example send SMS: “stopelec123456”.
"stopoil" as instructions, "123456" as the password.
To supply the circuit again, send SMS “supplyelec+password” to the unit. For example, send SMS “Supplyelec123456” to the tracker. "Supplyelec" as instruction, "123456" as password.
8. Monitor mode
There are three modes for monitor.
1) All Monitor Mode: Send SMS “AllMonitor” to the unit, the unit will return to this mode. In this mode, any number can monitor this unit.
2) Restrict Monitor Mode: Send SMS “RestrictMonitor” to the unit, the unit will return to this mode. In this mode, authorized number can monitor this unit.
3) Close Monitor Mode: Send SMS “CloseMonitor” to the unit, the unit will return to this mode. In this mode, all numbers can not monitor this unit.
9. Movement alert
Set up: The user can send SMS “Move + password” to the unit, then the unit will reply “move ok!” .In case of such a movement, it will send SMS “Move” along with a Geo-info to the number.
For example, send SMS “Move123456” to the unit. "Move" as instructions, “123456”as password. &nbs