Fire Fighting alarm control panel with release button gas extinguishing building fire security

Price: 268.0 USD
Trade Term: FOB,EXW
Payment Terms: T/T,WU,Paypal
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: Vedard 
  • Fire linkage type: Conventional Fire Alarm System 
  • Security and Protection: Building Fire fighting 
  • Fire detection zones: 4 zones fire detection 
  • Fire detection sensors: smoke detector, heat detector, gas sensor, manual call point 
  • size: 383mm W*295mm H *87mm D 
  • Model No.: CM1004 
  • Place of Origin: Fujian  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Air
Supply Capacity
  • Production Capacity: 1000 per month
  • Packing:in one carton per piece
  • Delivery Date: in 5 days

The design and installation of fire detection and alarm systems will help save lives and protect property and the environment. The system will detect a fire inside or outside a structure as early as possible and give building occupants early warning of fire. So it gives more chance of reducing human and material losses. In order to work well, a fire detection and alarm system must be installed and maintained correctly by experienced personnel. CM1004 is new type conventional fire alarm control panel with gas extinguisher component.

It is used on smaller projects such as small schools, stores, restaurants, and apartments where flammable gas maybe produced as well. CM1004 is capable of using solenoids and extract fan and igniting actuator to fight fire. It has manual release switch and automatic release switch for fire fighting. All of the 4 detection zones or any of which are capable of contributing to the extinguisher release decision.
It is with gas leakage pressure detection switch and extinguishing released upon pressure switch operated. There are relay contacts of fault relay, fire relay, 1st stage alarm, 2nd stage alarm, extract relay.
Under test condition, it is allowed to automatic resetting of zones in alarm for testing purposes with requirement of EN54-2 section 10.

In addition to the requirements of EN54-2, all control panels have voltage free relay contacts for fire and local fire which operate upon a fire condition.
Activation of alarm devices are with different sounds signals to indicate pre-discharge and released warning.
CM1004 is new technology fire alarm system meets new fire alarm requirement. It allows a remote source to sound the alarms with class chnage facility. The fire alarm panel can connect to repeater with 4-wire connection with RS485 data carring.

It is a combined fire alarm control panel and extinguishing system with 4 detection zones. 
It can automatically release fire extinguishing and activate solenoid electric valve, extract fan and igniting actuator.
It is with extinguishing release button on alarm panel for manual activate gas extinguishing. 
Panel operation can be enabled or disabled. 
It is with gas leakage pressure detection switch and extinguishing released upon pressure switch operated. 
There are evacuate, silence, Test, reset and extract fan button on panel for operation. 
Two NAC circuits for sounders output and can be enabled and disabled on panel. 
There are relay contacts of fault relay, fire relay, 1st stage alarm, 2nd stage alarm, extract relay. 

Technical specification:
Size: 383mm W*295mm H *87mm D metal enclosure
Main power supply: 90-270VAC 50Hz/60Hz
Power supply current: 3Amps total including battery charge 28V +/-2V
Battery type: Two 12 volt sealed lead acid in series.
Current draw in post discharge condition with solenoid output active: 0.31Amps
NAC outputs(sounder and bell circuit): 26 -28V DC fused at 500mA with electronic fuse
Number of detectors per zone: <=30 pcs conventional detectors
Number of sounders per circuit: Dependent on type and current consumption
Extinguishing release output: 21V to 28V DC. Maximum load 2Amp
Extinguishing release delay time: Adjustable 0 to 75 seconds
Status unit/ancillary board connection: two wire RS485 connection with electronic fuse 
Max. of 32 units-RS485 data cable


Send message to this supplier