Effluent Decontamination Veterinary Autoclave Steam Sterilizer For Animal Labs

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

Effluent Decontamination  Veterinary Autoclave SS 304 Chamber For Animal Labs
 
 
Specification:

Model

Chamber Size

Overall Size

Net Weight

Steam

Water

Power

W*H*D mm

W*H*D mm

Kg

Kg/cycle

Kg/cycle

KVA

MD-0.11V

400*400*700

1000*1800*1040

650

14

215

2

MD-0.16V

400*400*1000

1000*1800*1340

700

16

220

2

MD-0.20V

400*400*1300

1000*1800*1640

750

18

225

2

MD-0.24V

600*600*670

1200*2000*1010

800

20

230

2

MD-0.30V

600*600*840

1200*2000*1180

850

22

235

2

MD-0.36V

600*600*1000

1200*2000*1340

900

25

240

2

MD-0.45V

600*600*1250

1200*2000*1590

980

27

250

2

MD-0.60V

600*600*1670

1200*2000*2010

1100

30

260

3

 
Program Parameter
 

Cycle name

Further details

Application

Instruments/Tools

3 times Vacuum, expose temperature 132, expose time 8 min, drying time 5 min.

Solid materials to be sterilized:
Packaged instruments
Empty glass containers
Empty metal containers
Porous materials to be sterilized:
Rubber articles

Clothing

3 times Vacuum, expose temperature 121, expose time 15 min, drying time 25 min.

Materials to be sterilized from which air can’t be easily displaced
Textile

User Programmable

All preset parameters can be reset; Multiple customized programs can be set and stored by user.

Customized

Test programs and utilities

B-D Test

3 times Vacuum, expose temperature 134, expose time 4 min, drying time 3 min.

Test program

Vacuum Leakage Test

Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect.

Test program

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Piping, fittings, and       valves are available in       stainless steel or brass/bronze.
All parts and components subject to repair are publicly available (i.e. non-proprietary) from o
pen market sources, including controls, valves and fittings.
Safety relief valves and drains are integral to the plumbing configuration.
Baffled steam inlets minimize   direct condensate on the load, reduce load wetting, and help
assure proper steam uniformity within the chamber.
Cabinet       insulation retains heat and minimizes heat loss to the room. The sterilizer jacket and
all steam service piping include a minimum 1" mineral wool-based insulation.
An  integral waste water cooling function reduces discharge temperature to the Drain to
less than 140°F (60°C).
On  units equipped with steam  generators, an pressure switch is included to back up
the safety relief valve by automatically shutting down the steam generator if an over
pressure condition exists.
Easy-to-read pressure gauges ensure simple and safe operation.
Other components required for the intended application may include a steam generator,
vacuum pump, water ejector, etc. depending on the options chosen.
 
Description:
 
Feature of the veterinary autoclave is the control of the sterilization phase according to
a pressure signal, rather than temperature. Obviously, the temperature readout varies as
a function of the position of the sensor, whilst the pressure is uniform throughout the
chamber.However, process control is performed by reading in the chamber
(and from inside the product) temperature signals whose match with the pressure value,
as constantly verified by the controller, demonstrates that the autoclave is operating correctly.
This principle, in saturated-steam conditions (when there is a two-way T/P correspondence)
allows to obtain uniformities in sterilization temperature which are far better than the
currently required level of ±0,5 °C.
 
Applications:
 
“Un-Wrapped Goods and Wrapped Goods”,“Small volumes of Liquids” and “Rubbers and alu caps”
 
Competitive Advantage:
 
Effluent Decontamination.
Available on gravity and pre-vacuum units. Retains liquid effluent, if any, within the chamber
for the duration of the sterilization cycle. Aerosol effluent passes through a 0.2 micron
hydrophobic HEPA filter with >99.999% efficiency; the filter is located within the chamber
and is sterilized in situ to eliminate the need for disposal after each cycle. The filter is
easily replaced by the user when required without special tools or service personnel.
 


Send message to this supplier
Mr. Ms. JULIET
Tel: 86-512-58688450
Enter between 20 to 3,000 chatacters.
Contact Method
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
B631 ROOM,HUAFANG INTERNATIONAL MANSION,NO.178 CHENGBEI STR., Suzhou, Jiangsu, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center