Glutaraldehyde Fumigation Cabinet Service

Trade Term: FOB,CFR,CIF
Payment Terms: T/T,L/C,WU
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: ANERSON 
  • Volume: 280L 
  • Ozone: yes 
  • Glutaraldehyde Fumigation: yes 
  • Output: 320W 
  • Size: 55*135*46cm 
  • Ozone concentration: ≥60mg 
  • Place of Origin: Henan  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air
Supply Capacity
  • Production Capacity: 500sets per month
  • Packing:1set in volid wood carton with polyfoam inside
  • Delivery Date: 7-30days depends on quantity

 We are seeking global co-operation agents for our products.          

Glutaraldehyde Fumigation Cabinet Automatic Device


1.Superiority of the evaporator and the separation of the smoke box:


The traditional formaldehyde fumigation box is mainly of disinfection and sterilization by chemical fumigation, high temperature heating method and natural evaporation method, due to the evaporation of formaldehyde is carried out in the cabinet, it is difficult to avoid the direct damage to personnel, liquid reservoir and the control center design of the cabinet in the box body back, liquid through the pipeline quantitative input to the evaporator, the utility model has the advantages of are as follows:

Can protect the safety of electric energy system, will not be due to the failure of the wet, the evaporator works stable, long service life, easy maintenance

After disinfection, the gas can be discharged smoothly, leaving no residual gas

The whole disinfection process is done by the electronic control program, which avoids the stimulation to the human.

Cabinet and liquid is not down, not open the door, convenient, fast, accurate, does not affect the disinfection cabinet sterilization and disinfection of pollution

2.Multi-function Introduction



a.LCD Chinese display

b.the main control function: imported MCU microcomputer control program

c.upper work (sterile storage) layer of glutaraldehyde fumigation disinfection

d.temperature display, humidity display

e. disinfection time 3---6 hours can be adjusted

f. ultraviolet alarm and work time

g. lack of liquid alarm function

h.evaporator failure

i. quantitative liquid

j. the residual glutaraldehyde gas treatment,

k. air pre disinfection function

l. automatic discharge of waste liquid


3.Glutaraldehyde sterilization process


Pre heating temperature and humidity of liquid evaporation and humidity of the wet and constant temperature and humidity

Glutaraldehyde sterilizing cabinet instrument: endoscope: various types of rigid, flexible stomach, colonoscopy, arthroscopy, bronchoscopy, colonoscopy, choledochoscope, laryngoscope, nephrolithotomy,, commonly used medical devices, orthopedic drill, micro instruments, a variety of medical plastic products, wire tube, a conduit, diathermy cable. All metal, rubber, glass and other equipment, in particular, afraid of high temperature and high pressure, afraid of wet, afraid of corrosion equipment equipment.


On the characteristic of glutaraldehyde disinfection, the molecular formula of glutaraldehyde was C5H8O2, and the molecular weight was 100.13. It was colorless or light yellow liquid, soluble in water and alcohol, soluble in water (PH3 - 4). Preparation of 2% alkaline glutaraldehyde in 1963 began to be used for disinfection. Glutaraldehyde has a broad spectrum, highly effective bactericidal effect, is highly effective sterilization agent. Has the advantages of small corrosive, small impact of organic matter. The main germicidal mechanism: 1, direct damage to the bacterial protein, glutaraldehyde two lively aldehydes can react with the peptidoglycan reaction, resulting in peptidoglycan cell rupture; 2, and make it unable to reproduce, in cells of living matter, nucleic acid. Control the synthesis of DAN and RNA, so that the nucleic acid material can not be formed. 3, different concentrations of glutaraldehyde bactericidal effect has obvious difference, high concentration of glutaraldehyde after gasification, the effect is better and more efficient. Widely used in disinfection and sterilization of medical instruments and precision instruments. (from the 2002 edition of "technical standard for disinfection" 3.1.8.1). Compared with the formaldehyde disinfection cabinet used in hospital, the more economical, more convenient and more obvious effect of glutaraldehyde disinfection cabinet. Formaldehyde on the human body has carcinogenic effect, the effect of environmental temperature is not stable, and glutaraldehyde on the human body non-toxic side effects, and the metal medical equipment, so the national Ministry of health in 2002 edition of "disinfection technical specifications" clearly pointed out that the use of glutaraldehyde instead of formaldehyde disinfection.


4.Note:

 using glutaraldehyde fumigation disinfection products emerged in recent years, experienced users and manufacturers are not many, glutaraldehyde fumigation method and formaldehyde fumigation has many different, for ease of use, we now avail ourselves of this opportunity for promotion expounds some problems we found in the after-sales service, for your reference.

The glutaraldehyde fixed brand, do not use extended

Attention to the regular observation of reduced glutaraldehyde plus liquid, cycle frequency is normal

Glutaraldehyde] after fumigation, will produce residual crystallinity, its color is brown, attachment in the chest wall and the surface of the object will be mistaken for through spot users per week for regular cleaning, especially cabinet door and the cabinet body is in contact with the sealing surface, due to long time does not wash adhesion, easy damage sealing strip lead to leakage. (gauze can be cleaned);

The goods should be performed prior to fumigation by aseptic manual cleaning

The environment should have ventilation equipment, ventilation equipment should be enabled during the reign of personnel

The sterile storage

The deposit items for more than five days to re disinfection;

] gas fumigation after cooling, condensation down into the bottom of the water receiving disc users please emissions on a regular basis clean-up, never thought to be leakage of glutaraldehyde

we are seeking global co-operation agents for our products.



Send message to this supplier
Ms. Lily
Tel: 86-371-85967588
Mobile: 13803896700
Enter between 20 to 3,000 chatacters.
Contact Method
Zhengzhou Safute Electronic Equipment Co., Ltd.
B-9th Floor, Torch Building, No. 8 Guohuai Str, High & New Technology Industries Development Zone, Zhengzhou, Henan, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center