UART interface Wireless M-bus Module FC-703C for water,gas and heat meter reading

 

 
 
1. Technical Specification

 
 
ItemMinTyp.MaxUnit
Frequency bands868 870MHz
Number of channels12
Supply voltage VCC2.03.33.6VDC
Voltage on any pinVCC-0.7 VCCVDC
TX Current (RF_POWER=5/10dbm) 40 mA
RX Current 24 mA
Sleep Current 0.6 uA
Input/output impedance50Ohm
RF Data rate4.8
32.768
100
kchip/s
Max RF output power(VCC=3.3V) 10 dBm
Sensitivity, 32.768K-102dBm
Spurious emission, TX
< 1 GHz
> 1 GHz
-36
-30
dBm
Sensitivity(32.768K)-102dBm
Blocking
1 MHz
4 MHz
8 MHz
–52
–56
–63
dBm
Image Rejection–30dBm
Spurious Emissions-54dBm
Harmonics–42dBm
Minimum RST Low Time to
Generate a System Reset
15μs
Operating temperature-40 80°C
Storage temperature-50 150°C
Weight 5 g

 

 

2. Brief Description

FC-703C RF transceiver module follows the wireless M-BUS protocol.  It has a UART interface for serial communication and configuration. The dimension is 13.7*25.4*3.4mm.FC-703C can work in S, T, R2 and C mode. It works in sleeping mode with super-low consumption power and be wakened up via serial port. By mounting the module onto the user board, it is easy to use through serial port communication protocol.UART interface Wireless M-bus Module FC-703C is a good choice for water,gas and heat meter reading.
 


 
3. Main Applications
AMR/AMI
Electricity meters
Gas and Water meters
Heat meters, Heat cost allocators
Handheld device and gateways
In-Home Display and wireless sensor

 

4. Pin Assignment and Description

PinNameDescribe
1GNDGround
2-7RESERVEDFor test and future extension, not connected
8RTSReceive flow control I, output, high: idle, low: busy.
9CTSSend flow control O, input high: idle , low: busy
10RESERVEDFor test and future extension, not connected
11CONFIGReserved
12GNDGround
13GNDGround
14VCCPOWER SUPPLY
15GNDGround
16GNDGround
17RFRF pin, connect with antenna
18GNDGround
19GNDGround
20-24RESERVEDFor test and future extension, not connected
25LED1LED1 output. If not needed, not connected. Active high.
26LED2LED2 output. If not needed, not connected. Active high.
27RXDSerial RX
28TXDSerial TX
29RESETReset Pin (active in low)
30GNDGround

 
 
5.Typical Application Description

 

 

 

 
 


Send message to this supplier
Mr. Miss. Victoria
Tel: 86-755-23230518
Enter between 20 to 3,000 chatacters.
Contact Method
Shenzhen Friendcom Technology Development Co., Ltd.
6/F, 17 Building, Guangqian Industrial Park, Shenzhen, Guangdong, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center