Flame Retardant RS485 Databus Cables LSZH Sheath

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Flame Retardant RS485 Databus Cables Application:Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol,Website:http://www.ue-cable.com, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.Standard:Basic design to EIA/TIA 485FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING60VCABLE CONSTRUCTION Multipair RS 485 Overall Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall screen: Aluminum/polyester tape with tinned copper drain wire. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Overall Double Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall screen: Aluminium/polyester tape+copper wire braid. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Individual & Overall screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Overall Screen: Copper wire braid. outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Overall Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall Screen: Copper wire braid. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -20°C - +90°CTemperature range during installation (mobile state): -5°C - +60°C Minimum bending radius: 8 x Overall DiameterElectrical PropertiesDielectric test1000 V r.m.s. for 5' (core-core)1000 V r.m.s. for 5' (core-screen)Impedance120Ωcapacitance45 nF/km conductor to conductor90 nF/km conductor to shieldCONSTRUCTION PARAMETERSMultipair RS 485 Overall Screened Databus Cable RE-02Y(St)H / RE-02YS(St)HNo.of pair xNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.02120.227/0.20.550.407.14240.227/0.20.550.408.36810.5016/0.20.550.404.63220.5016/0.20.550.408.26840.5016/0.20.550.409.811510.7524/0.20.550.405.14020.7524/0.20.550.409.18440.7524/0.20.550.4010.914411.0030/0.20.550.405.24921.0030/0.20.550.409.510541.0030/0.20.550.4011.2182Multipair RS 485 Overall Double Screened Databus Cable RE-02Y(St)CH / RE-02YS(St)CHNo.of pair xNominal  Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.53420.227/0.20.550.407.56740.227/0.20.550.408.89710.5016/0.20.550.405.14820.5016/0.20.550.408.79740.5016/0.20.550.4010.315010.7524/0.20.550.405.65720.7524/0.20.550.409.711640.7524/0.20.550.4011.418211.0030/0.20.550.405.76721.0030/0.20.550.4010.013841.0030/0.20.550.4011.8222Multipair RS 485 Individual & Overall screened Databus CableRE-02Y(St)H pimf / RE-02YS(St)H pimfNo.of pair xNominal  Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.43520.227/0.20.550.407.56940.227/0.20.550.408.810610.5016/0.20.550.405.04920.5016/0.20.550.408.710040.5016/0.20.550.4010.315910.7524/0.20.550.405.55820.7524/0.20.550.409.711940.7524/0.20.550.4011.217411.0030/0.20.550.405.66821.0030/0.20.550.4010.014241.0030/0.20.550.4011.8234Multipair RS 485 Overall Screened Databus CableRE-02YCH / RE-02YSCHNo.of pair xNominal  Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.33120.227/0.20.550.407.36140.227/0.20.550.408.59110.5016/0.20.550.404.94420.5016/0.20.550.408.59140.5016/0.20.550.4010.014210.7524/0.20.550.405.45320.7524/0.20.550.409.510940.7524/0.20.550.4011.217411.0030/0.20.550.405.56321.0030/0.20.550.409.813141.0030/0.20.550.4011.5213
Send message to this supplier
Ms. HelenWong
Tel: 86-531-88817113
Enter between 20 to 3,000 chatacters.
Contact Method
UNIVERSAL CABLES LIMITED
1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China, Jinan, Shandong, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center