Specifications:

Nominal Voltage 6V
Nominal Capacity (C20) 7Ah (5.25V,at 25)
Dimension Length 151mm
Width 34mm
Height 94mm
Total Height 100mm
Weight Approx. 1.15 kg
Terminal FO-02/FO-03
Internal Resistance Approx. 15 mΩ (25)
Max Charging Current 2.1A

 

 

CHARGE

Using Mode Charging Voltage Temperature Compensation Max Charging Current
Standby Use 2.275±0.025V/cell (25) -3.3mV//cell 2.1A
Cyclic Use 2.45±0.05V/cell (25) -5mV//cell

 

 

 

Description:

Designed life for floating charge is 2~3 years (20);

Gas Recombination;

Wide temperature scope of application (-15~45);

Best temperature of application (20±5);

No leaking, safe and reliable;

Standing or lying down for using, convenient to transport and install;

High sealed reaction efficiency, little loss of water, no need to add distilled water or electrolyte, simple to use and maintain;

Application specific design.

 

 

 

Applications:

Alarm & Security system

Emergency Power Systerm

Fire-safety Emergency System,

Banks & Financial Centre

Hospital& Testing Laboratories

Telecommunication

 

 

 

STORAGE

Batteries should be stored in dry and clean warehouse which has good air exchange system. Batteries should avoid direct sunlight. Batteries should not be near to heat (such as radiator, the distance should more than 1m). Batteries should avoid any toxic gas and organic solvent.

When the ambient temperature is less than 25, the longest storage life is 6 months. If ambient temperature is higher, the longest storage life varies as specified in below chart.

Storage Temperature () ≤25 2633 3440
Storage Time (Month) 6 3 1
 

 

Batteries should be recharged within the storage life or before using.

Charging methods: maximum charging current 2.1A, constant voltage 2.45±0.05V/cell (25);

Charging time: 15~20h; Temperature compensation coefficient: -5mV//cell.

 

 

TECHNICAL FEATURES:

• Sealed Construction

The unique construction and sealing techniques of the battery guarantee leak proof operation in any position with no adverse effect to capacity or service life.

 

• Electrolyte Suspension System

All batteries utilize an electrolyte suspension system consisting of a high porosity, glass fiber material which in conjunction with plates, totally absorb and contain the electrolyte.

 

• Gas Recombination

CGB batteries incorporate a built-in design that controls gas generation and induces recombination of more than 99% of gases generated during float or cyclic usage.

 

• Maintenance Free Operation

Due to the perfectly sealed construction and the recombination of gasses within the cells, the battery is almost maintenance free.

 

• Low Pressure Valve Regulated System..

All batteries are equipped with safety release valves, designed to operate between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is never an excessive accumulation of gas within the battery.

 

• Heavy Duty Grids

Heavy duty lead calcium tin alloy grids provide an extra margin of performance and service life in either float or cyclic applications.

 

• Cyclic Service Life

More than 600 discharge/recharge cycles can be realized from CGB CB and HR batteries, dependent on the average depth of discharge.

 

• Float Service Life

SE and CB, HR Series batteries have an expected life span of 3 to 5 years in float service applications.

 

• Self Discharge - Shelf Life

The self discharge rate at room temperature is approximately 3% of rated capacity per month.

 

• Operating Temperature

CGB Batteries may be operated over a broad range of ambient temperatures.

 

• Deep Discharge Recovery

The batteries recover their capacities even after repeated deep discharges.

 

Caution

1. Don’t near the hot source and don’t under the sunshine.

2. Don’t charge in the sealed container.

3. No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.

4. Don’t store in the space of acid gas.

5. You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using.

6. Don’t put the battery in the fire, or it will explode.

7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

 


Send message to this supplier
Mr. Mr. Gao song
Tel: 86-27-84891323
Enter between 20 to 3,000 chatacters.
Contact Method
Wuhan Changguang Battery Co., Ltd
WuhanEconomicTechnologyDevelopment Zone, Wuhan, Hubei, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center