Common Atomic Absorption Spectrophotometer

Price: 1.0 RMB
Trade Term: FOB
Payment Terms: T/T,L/C,D/A,D/P,WU,Paypal,Money Gram;Cash
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Spectrophotometer: Absorption Spectrophotometer 
  • Atomic Absorption Spectrophotometer: Atomic Absorption Spectrophotometer 
  • Model No.: GD-320N 
  • Place of Origin: Chongqing  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 500Sets/per Month
  • Packing:Wooden Case
  • Delivery Date: 10days

GD-320N Atomic Absorption Spectrophotometer

Specifications:

Working spectral range

190-900nm

Wavelength accuracy

≤ ±0.5nm

Wavelength repeatability

≤ 0.3nm (single direction)

Spectrum bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Resolution

<40%

Base line stability

±0.004Abs/30min

Characteristic concentration of copper

≤ 0.04mg/ml/1%

Detection limit of copper

≤0.008mg/ml

Background calibration ability

Greater than 30 times

Standby Interface

RS 232

Instrument power supply

220V, 3A, 50Hz

 

Features:

v Build-in computer data pr℃essing and LCD 

Adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

 

v Good basic line stability 

Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

 

v High precision of measurement

Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.

 

v Optical path of high energy

A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.

  

v Long-life and anti-corrosive atomization system

The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

 

v Multi-functional analysis mode

For methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.

 

v Safe and reliable gas path system

Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame.

 

v Complete set of accessories 

To be supplied with the instrument and ready for use after they are purchased.

 

v Light-source system

Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply: with fixed current

 

v Optical system

Double beam total refection system, C-T type mon℃hromator Flashing wavelength: 250nm

 

v Flame atomization system

Inter-changeable titanium alloy burner of 250px and 125px slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interl℃k protection devices.

 

v Signal pr℃essing

Absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

Accessories:

v Air compressor;

v One piece of Cu hollow cathode lamp;

v Gas external pipe;

v Acetylene cylinder pressure-reducing valve;

v Water kn℃kout gas filter;

 

Optional Accessories:

v GA3202 HGA graphite furnace system 

Used to conduct trace and ultra-trace analysis with an absolute sensitivity of 10-10-10-12 gram.

v 125px long-life titanium burner

The necessary accessory for nitrous oxide-acetylene flame analysis.

v Hydride generator (Totally automatic)

Making the characteristic concentration of As, Se, Sb, Bi, Pb, Sn, Te, Ge, In, Tl, Cd and Zn lower than ppb level with cold atomic mercury measurement method.

v Hollow cathode lamp

All specifications are available.

v Graphite tube

All specifications are available.

v Software with I/O port

v Printer



Send message to this supplier
Ms. cathy Jiang
Tel: 86-023-62984891
Enter between 20 to 3,000 chatacters.
Contact Method
Gold Co.,Ltd
9F/10,Jintai Building,Nanping, Chongqing, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center