XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32

 

 

 

Structure

 

1 ..... stranded bare copper
2 ..... inner layer of semi-conducting material
3 ..... core insulation of cross-linked polyethylene
4 ..... outer layer of semi-conducting material
5 ..... semi-conducting tape
6 ..... screen of copper wires

7 ..... Fillers strip, Yarn, or Paper
8 ..... Non woven Wrapping tape or Flame Retardant

9 ..... Extruded PVC Inner Covering

10 .... Galvanized Steel Tape Armoured
11 .... Overall Sheath: polyvinylchloride (PVC) or FR-PVC, PE, LSOH

 

 

Application


Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.

Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability.

Used in transformer stations, switching blocks, in electric power plants and industrial plants.

To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

 

 

Standard

 

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

 

 

Specification

 

MV(6 to 35kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV No.of Core Conductor cross-section area(mm2)
xlpe insulation 1 core 3 core 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core Al Core
YJV, N2XSY;PVC sheathed power cable YJLV, NA2XSY; PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable YJLV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable
pvc insulation
Cu Core Al Core
VV(VY);PVC(PE)sheathed power cable VLV(VLY);PVC(PE)sheathed power cable
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable

 


Technical data

 

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables

 


 

Certificate

 

ISO,CE, KEMA ,IEC, RoHS, CCC, P3C and more others at request

 

 

Ordering

 

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

 

Technical Parameter

 

Nom. Cross-section of conductor Strands No./Dia. Of Conductor Insulation Thickness Inner Sheath Thickness Dia. Of Armor Wire Sheath Thickness Approx. O.D. Approx.Weight Max. D.C Resistance of Conductor (20 ) Testing Voltage A.C Current Rating
mm2 pc/mm mm mm mm mm (mm) kg/km Ω /km kV/5min In air (A) In soil(A)
3 × 25 7/2.14 3.4 1.3 2.5 2.5 49.0 4579 0.727 21 120 125
3 × 35 7/2.52 3.4 1.3 2.5 2.6 52.0 5097 0.524 21 140 155
3 × 50 10/2.52 3.4 1.4 2.5 2.7 54.0 5802 0.387