Anti - Corrosion Riased Floor Access Thermal Insulation CIACA Standard
HT Antistatic Calcium Sulphate Riased Access Floor with Excellent Corrosion Resistance and Thermal Insulation Performance adopts high-density core which is processed and solidified into calcium sulphate crystal. For surface, HT chooses High Pressure Laminate (HPL)as covering. For base plate, HT uses steel galvanized steel with conductive black edge trim sealed on four edges. HT Antistatic Calcium Sulphate Riased Access Floor with Excellent Corrosion Resistance and Thermal Insulation Performance has become most widely-used material in many countries.
Application
HT Antistatic Calcium Sulphate Riased Access Floor with Excellent Corrosion Resistance and Thermal Insulation Performance is specially suitable for enterprise or public institution’s high-grade server rooms. Especially for telecommunication equipment rooms, intelligent office rooms, etc.
Characteristics
- Flexible understructure compensates the unevenness and improves flatness
- Good interchangeability and high assembling accuracy
- Stable form and dimension enables its wear-resistance
- Great flexibility offers properties which can be integrated with other systems
- Fibre-reinforced material guarantees non-toxic and non-polluting properties
- Cracking seldom occurs which enables its durability
Technical Paramter
Type | Size | Uniform load | Concentrated load | Rolling load | Ultimate load | System resistence | ||
0.100''/2.5mm DEFLECTION | 10PASS | 10KPAAASS | ||||||
Medium Duty | 600*600mm 800*800mm | 22.22 | 4.45KN | 454kG | 3.56KN | 2.67KN | 14.50KN | Conductive: 104-106Ω Dissipative:106-1010Ω |
Extra Heavy | 27.78 | 5.56KN | 567KG | 4.45KN | 3.56KN | 18.36KN | ||
Extra Heavy Duty | 33.34 KN/ | 6.68KN | 680KG | 5.56KN | 4.45KN | 22.17KN |
Installation
Main Tools Include
Large push cutter, Infrared ray level instrument, Panel lifter, Screw driver, Wax wires, Level bar, Adz-eye Hammer, Nail, Pencil, Flexible rule, Pedestal adhesive, Tool bag, Broom, etc.
Position Datum Point
Proper datum point can avoid the waste of room, the best choice is to set the intersection point of two walls which are rectangular as datum point. If there is a ramp at door, or space for door to swing, the best datum point should be near door. If designing or partition drawing has marked datum point,it can be considered as final.
Notice
- Datum line: A straight line paralleled to datum line,the longest distance between datum level and datum line is 600mm
- Datum level: It is a wall which owner requires to be installed with whole floor panel.
- Vertical: It is a straight line which is vertical to datum line.The largest distance between the vertical line and adjacent wall is 600mm.
- Note: Pls contact sales for detailed installation method.