                               All aluminum bare conductor AAC AAAC ACSR for ASTM standard of High Voltage

 

   Product Description
 

Specifications

All Aluminum Alloy Conductor
1. Voltage: Up to 500kV
2. Standard:IEC 60889 BS 215 ASTM B 232
3. Size:10-1000sqmm

 

1 Application

 

AAAC (All Aluminum Alloy Conductor) referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR; Having lower breaking loads than the latter, their use becomes particularly favorable when ice and win loadings are low.

We can supply this conductor according to different recognized standards, such as BS EN50182, IEC61089, ASTM B399DIN 48, customer special specification also can be satisfied.

 

 

 

2 Service Performance

 

Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords

better sag characteristics.

- Aluminum alloy AAAC-6201 offers higher resistance to corrosion than ACSR.

- Aluminum alloy (AAAC) contains a small percentage of silicon and magnesium elements. It provides several benefits for overhead lines

 

3. Product Performance

Bare conductor AAC AAAC ACSR for outdoor overhead power transmission

(1).The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ. m of international standard value.

(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.

(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.

a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.

b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.

 

4. Material Standard

Bare conductor AAC AAAC ACSR for outdoor overhead power transmission

(1). The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048- 1997(equivalent to IEC 60889:1987).

(2). The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.

(3). Production can be arranged according to customers requirements for material standard,etc.

Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced

 

5. Chinese Standard

 

Code name

Aluminum

Area

Stranding&

Wire Diameter

Approx

Overall

Diameter

Approx

Weight

Breaking

Load

DC

Resistance

Al Steel
AWG mm2 No./mm No./mm mm Kg/km KN Ohm/km
Turkey 6 13.30 6/1.68 1/1.68 5.04 53.75 5303 2.157
Swan 4 21.18 6/2.12 1/2.12 6.36 85.57 8302 1335
Swanate 4 21.12 7/1.96 1/2.61 6.53 99.56 10642 1352
Sparrow 2 33.59 6/2.67 1/2.67 8.01 135.70 12653 0.854
Raven 1/0 53.52 6/3.37 1/3.37 10.10 216.20 19455 0.536
Quail 2/0 67.32 6/3.78 1/3.78 11.30 272.00 23529 0.426
Pigeon 3/0 85.14 6/4.25 1/4.25 12.80 344.00 29417 0.337
Penguin 4/0 107.20 6/4.77 1/4.77 14.30 433.40 37055 0.268
Waxwing 266800 135.00 18/3.09 1/3.09 15.50 430.50 30519 0.213
Merlin 336400 170.20 18/3.47 1/3.47 17.40 542.90 38487 0.169
Linnet 336400 170.60 26/2.89 7/2.25 18.30 689.90 62918 0.169
Hawk 477000 241.6 26/3.44 7/2.67 21.80 975.50 86011 0.120
Dove 556500 282.6 26/3.72 7/2.89 23.6 1142.00 100838 0.1030
Peacock 605000 306.2 24/4.03 7/2.69 24.2 1159.00 95861 0.0948
Drake 795000 402.5 26/4.44 7/3.45 28.1 1626.00 138669 0.0717
Rail 954000 483.8 45/3.70 7/2.47 29.6 1602.00 115626 0.0597

 

  AAAC Technical Characters Based on Standard BS EN50182
BS EN50182
Code Old Code Cross section No. of wires Diameter Mass per unit length Rated strength DC resistance at 20
Wire Conduct
Send message to this supplier
Mr. Mrs. Flora Lee
Tel: 86-371-67679195
Enter between 20 to 3,000 chatacters.
Contact Method
Jinshui Wire & Cable Group
6 Buildling,NO.1 Cuizhu Street,undefined, Zhengzhou, Henan, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!