Programmable AC DC Dielectric Voltage Withstand Test Equipment 5KV / 12mA

 

 


The main parameters:
 

1, the input characteristics: single-phase 47 ~ 63HZ, 115 / 230V ± 15% (optional), 3A
 

fuse
 

2, AC voltage test: rated output: 5KV / 12mA
 

3, the output frequency: 60 / 50Hz Selectable)
 

4, the output waveform: sine wave distortion <2%, crest factor 1.3 ~ 1.5
 

5, the upper limit setting: Range: 0.10 ~ 12.00mA, resolution: 0.01mA, accuracy: ± (2%
 

2 words) * 1
 

6, the lower limit setting: Range: 0 ~ 12.00mA, resolution: 0.01mA, Accuracy: ± (2% of
 

the set value +2 words) * 1
 

7, DC voltage test: rated Output: 6KV / 5mA
 

8, the output ripple: <5% (at 6KV / 5mA, linear load test)
 

9, the upper limit setting: Range: 0.02 ~ 5.00mA, resolution: 0.01mA Accuracy: % Setting
 

value +2 words) * 2
 

10, lower limit setting: Range: 0.00 ~ 5.00mA, resolution: 0.01mA Accuracy: ± (2% of
 

the set value +2 words) * 2
 

11, : 200ms
 

12, Voltage setting: Resolution: 10V, Accuracy: ± (2% set value + 5V) Voltage
 

regulation: ± (1% set value + 5V) No load to full load
 

13, Rise time: Range: 0,1 ~ 999.9s, resolution: 0.1s
 

14, the test time: Range: 0,0.2 ~ 999.9S, resolution 0.1S, (0 = continuous test)
 

15, the arc detection: can set the sensitivity: 0 ~ 9
 

16, voltmeter: Range: 0.00 ~ 6.00KV, Resolution: 0.01KV Accuracy: ± (2% of reading +1
 

words)
 

17, ammeter: Range: AC 0.10 ~ 12.00mA, DC 0.02 ~ 5.00 (1%) Accuracy: ± (2% of the
 

reading +1 words) Resolution: 0.01mA
 

18, programmable logic remote control: Input: Test, Reset Output: Pass,
 

19, test results expression: buzzer, LCD display and reading, remote control status
 

output
 

20, memory group: 5 groups of test conditions memory, each group has 4 kinds of test
 

mode (test-in-process)
 

21, keyboard security lock: keyboard security lock to prevent misuse of the operator or
 

program to modify
 

22 LCD display: 16X2 dot matrix, anti-white backlight
 

23, Temperature: 0 ~ 40 ,
 

24, relative humidity <80% RH
 

25, size: 89mm high X280mm wide X370mm deep
 

26, weight: 9kg
 

Insulation resistance test
 

1, the use of environmental protection, Output voltage setting: Range: DC 0.10 ~ 1.00KV,
 

Resolution: 0.01KV Accuracy: ± (2% reading + 2V)
 

2, the voltmeter: Range: DC 0.00 ~ 1.00KV, resolution: 0.01KV Accuracy : ± (2% of
 

reading +1 words)
 

3, high impedance table: Range: 1 ~ 1000MΩ (4 digits, automatic shift) Accuracy: ± (3%
 

reading +2 words) (7% of reading +2 words) Voltage <500V
 

4, the upper limit set: Range / Accuracy: the same high-impedance table, pitch: 1MΩ
 

5, the lower limit set: Range / Accuracy: : Pitch: 1MΩ
 

6, the test time: Range: 0,0.5 ~ 999.9s, resolution: 0.1s (0 = continuous test)

 


Send message to this supplier
Mr. Mr. Alex
Tel: 86-27-86925460
Enter between 20 to 3,000 chatacters.
Contact Method
Wuhan Electric Apparatus Research Institute
NO.1 Yangxin Road, Hanyang District,undefined, Wuhan, Hubei, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center