Portable 15" high resolution color TFT patient monitor

Price: 1.0 USD
Trade Term: FOB,CFR,CIF,CIP,CPT,FCA
Payment Terms: T/T,L/C,WU,Paypal,Money Gram
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: XianFeng 
  • patient monitor: patient 
  • monitor: monitors 
  • portable monitor: portable patient monitor 
  • Model No.: PM15 
  • Place of Origin: Sichuan  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 6000
  • Packing:380mm*380mm*360mm
  • Delivery Date: within 3 days

6 Multi-parameters Patient monitor

This portable 15-inch TFT high-definition display monitor is suitable for hospitals to monitor the patient's ECG, NIBP, SpO2, RESP, TEMP, PR/HR,ECG parameters, to provide doctors with accurate disease judgment data, the instrument is small, light weight, easy to carry!

Function:

1.  Display: 15" color TFT screen, high resolution: 1024×768 dpi;

2.  6 Parameters: Standard – 5-lead ECG/HR, NIBP, SPO2, Temp., Resp., PR; Optional – 3/12-lead ECG, single/double IBP, double Temp., Sun Tech NIBP, Masimo/Nellcor Spo2, ETCO2,BIS,CO;

3.  Patient Range: Suitable for Adult, Pediatric, Neonate;

4.  Multi-display interface: Standard, Large font, Trend Coexist, OxyCRG dynamic,

7 full ECG waveforms;

5.  Language: Built-in 8 language for choose (English, Chinese, Turkish, Spanish,French, Russian, German, Italian);

6.  Review: Maximum 720h tabular and graphic trends of all parameters, 1000NIBP  records and 200 alarm event;

7.  Battery: Built-in 2 hours rechargeable lithium battery, and battery volume  display. 4 hours rechargeable lithium battery (optional);

8.  Network: TCP/IP networking platform, connect with central monitoring system.Wifi central monitoring system (optional).

 


 

 

Feature:

1. Advance patient Manage: gender, full name, ID no., room no., bed no.,  weight,height, blood type, paced or not, remakes;

2. Multi-parameter board: Separated parameter board, main board, ECG board,SPO2 board, and NIBP board are independent;

3. Interface: Color, layout of each parameters can be set up by user need,bed to bed view display(optional);

4. Fanless: Use special fanless cooling technology in the device to provide users quiet environment;

5. Standby: Unique standby mode for energy saving and suspend monitoring;

6. Time delay: Time delay switch-off function to save data when monitor turn off suddenly;

9. Easy software update: Users can update monitor software by themselves;

10. Analysis: Real time S-T segment analysis, and 20 type arrhythmic analysis;SpO2 Pitch Tone Variation, Drug Dose Calculation and Hemodynamic Calculations;

11.Storage: external SD card slot enables memory extension(optional);

12. Data transfer: USB port to allow to transfer patient data to a PC (optional);

13. Special SINNOR F-6 Spo2 technology: which is as correct as Nellcor spo2 but cheaper than it(optional); 

14. Resistance to interference : Efficient resistance to interference of defibrillator and HF knife;

15. Other optional: Touch Screen, Printer, Wall amount, VGA connect 

Optional: Touch Screen, Printer, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, ETCO2, Sun Tech NIBP, Wall mount, VGA, Wifi 

Performance Specifications

Display

15"color   TFT

Rolling and   refreshing waveform display

Resolution:   1024×768

Multi   display selectable including:

Standard   display

Large-font   display

Trend   coexist display

OxyCRG   dynamic view display

7 full ECG   waveforms display

Bed-to-bed   view display(optional)

Trace

9 waveforms   (7 ECG, 1 SPO2 and 1 RESP)

Sweep   speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/s

Indicator

Power/battery   indicator light

QRS beep   and alarm sound

Battery

Rechargeable   lithium battery, 12v/4AH

Max.24 hour   for charging, 2 hours for continue working

Trend

Parameter   graphic and tabular trends:

5s/piece, 8   hours;

1min/piece,168   hours(24hour×7days)

5min/piece,   1000 hours.

Storage

NIBP: 1000   groups

Alarm: 200   groups

SD card   external storage (optional)

Alarm

User-adjustable   High, Medium and Low limits 3-level

 Audible and visual alarm

Networking

Connected   to central monitoring system

TCP/IP   netting platform

Wifi   connector (optional)

Recorder

Build-in,   thermal array

Plethysmogram   caveform:2 /3 channels

Record   mode: manual, on alarm, time-defined

Recording   width: 50mm

Printing   speed: 50mm/s

Recording type

Frozen   waveform record

NIBP recall   record

Trend table   record

Alarm   record

Fixed -time   record

Standard parameter 

ECG

Lead mode:                                5 –lead(R, L, F,   N, C) (3/12 lead ECG for optional)

Lead   selection:                          I, II,   III, avR, avL, avF, V

Waveform:                          3 and 7 channel selectable

Gain   selection:                        0.5mm/mv,1mm/mv,2mm/mv

Sweep   speed:                         6.25mm/s;12.5mm/s;25mm/s;50mm/s

Heart rate   range:                        Adult: 15~300bpm;

Neonate/pediatric: 15~350bpm

Accuracy:                                   +1bpm   or +1%, which is greater

Resolution:                            1bpm

Filter:                                            surgery   mode: 1~20Hz

Monitor model: 0.5~40Hz

Diagnostic mode: 0.05~130Hz

Scaling   signal:                           1mv, +3%

Protection:                         withstand 4000VAC/50   voltage isolation against electrosurgical interference and defibrillation

Alarm range:                             15~350bpm

S-T segment detection:                 

Measurement range:    2.0mV~+2.0mV                         

 Alarm Range:          -2.0mV~ +2.0mV

Accuracy:              -0.8mV ~+0.8Mv

Error:                 +0.02Mv

 

Arrhythmia analysis:         YES

SPO2

Measurement   range:        0~100%

Wave   speed:               12.5mm/s;25mm/s

Resolution:                1%

Accuracy:                 +2% (70-100%); 0-69%   unspecified

Alarm   range               0~100%

Lower perfusion   situation

 

Pulse Rate(PR)

Range:                 20~300bpm

Resolution:             1bpm

Error:                 +1bpm or +2%, whichever   is greater

 

NIBP

Method:                   Digital Automatic   oscillometric

Operation   mode :            Manual/Automatic

Auto   measurement time:      Adjustable (1~720min)

                            (1,2,3,4,5,10,15,30,60,90,120,240,480,720min)

Measurement   Unit:          mmHg/Kpa selectable

Measurement   types:         Systolic, Diastolic, Mean 

Measurement   Range:

Range of   Systolic pressure:    Adult: 40~270mmHg

Pediatric: 40~220mmHg

Neonate: 40~135mmHg

Range of   mean pressure:      Adult: 20~235mmHg

Pediatric: 20~165mmHg

Neonate: 20~110mmHg

Range of   diastolic pressure:    Adult: 10~215mmHg

Pediatric: 10~150mmHg

Neonate: 10~100mmHg

Over-pressure   protection:     Double safety   protection

Resolution:                 1 mmHg

Alarm:                     Systolic, Diastolic, and Mean

 

RESPIRATION

Method:                     RA-LL impedance

Measurement   range:           Adult: 7~120rpm;

Neonate/Pediatric: 7~150rpm

Apnea   alarm:                 YES, 10~40s

Resolution:                   1rpm

Accuracy:                    +2rpm

 

TEMPERATURE

Compatible   probe:             YSI or CYF

Measurement   range:           5~50℃

Resolution:                   0.1℃

Accuracy:                    +0.1℃

Refreshing   time:               about 1

Average   measuring time:       <10s

 

Others Safety:              

Safety level: Class I, type CF 

Dimension and Weight

Dimension:      28*42*1200px        

G.W:       <6.5KS 

Operation Environment

Temperature:    Working 0~+40℃

Transportation and storage –20~+60℃

Humidity:       working≤85%

Transportation and storage≤93%

Power:          AC 100-240, 50/60Hz


Send message to this supplier
Mr. Henry
Tel: 86-816-2536609
Enter between 20 to 3,000 chatacters.
Contact Method
MIANYANG XIANFENG MEDECAL INSTRUMENT CO.,LTD
NO.677TangfangAvenue,TangxunTown,Economic Development District, Mianyang, Sichuan, China (Mainland) / 621000
Fax: 86-816-2531598
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center