Gas Chromatograph

Price: 500.0~2000.0 USD
Payment Terms: TT
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Model No.: GC102AF/AT 
  • Place of Origin: Shanghai  
  • Means of Transport: Shipment
Supply Capacity
  • Production Capacity: 300pieces/month
  • Packing:wooden box
  • Delivery Date: 20days
Characteristics
 
Features:
Computer aided temperature control with high accuracy (less than -0.1~+0.1Degree)
All control and application parameters, including operation parameters of the detector, can be set up through keyboard. Functions, such as self-diagnosis, switch-off protection, document storage and transaction, limit temperature setup thermal trip valve setup, and FID auto-ignition are incorporated inside of the instrument.
Large-screen LCD display, supporting Chinese characters, can accurately and clearly present all temperature control setup values, actual values, TCD working electricity supply, sensitivity of FID magnifier, and etc.
The instrument supports packed column i.e. on-column sample injection. It is compatible with such devices as instantaneous vaporizing sample injection, gas sample injection with gas sample injection valves, and 0.53mm large diameter capillary column direct sampler.
Open-end computer system can apply RS-232 interface and FJ-2000 chromatogram workstation to achieve dual path communication control and data processing.
Large capacity column (300mm*280mm*270mm) is easy to be installed with packed column and large diameter capillary column.
Performance Indicators:
Temperature Control:
1.        Temperature control areas: gas chromatogram column, sampler, detector
2.        Temperature control range: 15 Degree-399 Degree of room temperature (increment by 1Degree)
3.        Temperature control accuracy: less than -0.1~+0.1Degree (measured at 200 Degree)
Flame Ionization Detector (FID):
1.        Detection limit: max 1*10-10g/s(sample C16)
2.        Drift: max 2*10-12A/h
Thermal Conductivity Detector (TCD):
1.        Sensitivity: min 1500mV.ml/mg(carrier gas: H2:sample: n-Hexadecane)
2.        Baseline noise: max 20uV
3.  Baseline drift: max 50uV/h 