FZN25-12D/T630-20 Type indoor AC high voltage load switches
FZRN25-12D/T125-31.5 indoor AC high voltage load switches-Fuse combination units

FZN25-12D/T630-20 Type Indoor AC switch is three-phase AC 50Hz, rated voltage of 12kV and indoor installations, for industrial and mining enterprises for distribution in clinics and substations and other occasions, as electrical protection and control facilities for the division and load current, loop current, no load transformer and cable charging current.
FZRN25-12D / T Δ -31.5 type indoor AC high voltage vacuum load switch- fuse combination units is three-phase AC 50Hz, rated voltage of 12kV for indoor installations for industrial and mining enterprises and other occasions to change the station distribution Institution for load control and short circuit protection purposes. Equipped with grounding switch can withstand short-circuit current. Actuator can be manual and electric, easy remote control three power system requirements.
FZN25-12D, FZRN25-12D-type load switch and the combination of electric three-phase are for city distribution and industrial power equipment of three phase ring network or terminal power supply ,for load control and short circuit protection. As the combination of electrical transformers and other electrical equipment on the protective effect than the circuit more reliable, more economical, especially for rings, double radiation power supply units and box-type substation.
Mainly technical parameters
No
Item
Unit
Value
1
Rated voltage
kV
12
2
Rated frequency
Hz
50
3
Rated current
A
 
 
4
Rated insulation level
1min power frequency withstand voltage
kV
Arc-quenching chamber fracture 30
(effective value)
Earth ,phase 42, insulating fracture 48
Lightning impulse withstand voltage (peak)
Earth ,phase 75, insulating fracture 85
 5
Rated dynamic current (peak)
kA
50
 
6
4S thermal current
kA
20
 
7
Rated power load breaking current
A
630
 
8
Rated closed-loop breaking current
A
630
 
9
Rated cable charge breaking current
A
10
 
10
Rated breaking no-load transformer capacity
kV
1250
11
Rated transfer current
A
 
2000
12
 Fuse model
 
 
SDLAJ-12
13
Striker output energy
J
2~5       
14
Rated short-circuit closed current
kA
50
80(predictive value)
15
Earth switch rated dynamic current
kA
50
16
Earth switch 2s thermal current
kA
20
17
Auxiliary circuit rated voltage
V
~220  ~110
18
Mechanical life
times
10000
19
Opening time of fuse trigger
ms
30~40
20
Opening time of tripper trigger
ms
40~50

Send message to this supplier
Mr. Tony
Tel: 86-577-27863960
Enter between 20 to 3,000 chatacters.
Contact Method
Phenix Group Co.,Ltd.
Jiaxi, Liushi Town, Yueqing City, Wenzhou, Zhejiang, China (Mainland) / 325604
Fax: 86-577-27863970
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center