Main Features:
Easy-to-fit wire rope sensor
2 measuring channels
Easy calibration with no need of foreknowing weight
Signal output of zero load, heavy load and overload
Support in-circuit programming and upgrading of the system software
User-defined overload factor
Automatic learning function of floor accurate compensation
Analog voltage output 0~10V, -10~10V
Analog current output 4~20mA
Sensor A and C are fitted with steel rope. Sensor B and D are fitted with rope hitch plate.
Technical Parameters
Load Sensor | Controller | ||
Rope Diameter | 6mm~16mm(A) | Supply Voltage | AC/DC14V~65V |
Measuring Range | 0~5000kg | Power Rating | ≤4W |
Overload Factor | 150% | Alarm Relays | Light load, heavy load, overload |
Connection Cable | 14m | Analog Voltage Output | 0~10V, -10~10V |
Ambient Temp. | -20℃~70℃ | Analog Current Output | 4~20mA |