Model ZLT-HV4
The ZLT Horizontal-Vertical Flammability test apparatus is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. The device complies with UL1581-2001(1060 FT1, 1061, 1080VW-1, 1090, 1100FT2) standards-related requirements designed. Applicable to the single wire and cable, and soft-line horizontal (FT1), vertical (VW1) combustion test. Burning time and burning the number of adjustable, can be automatic / manual, vertical / horizontal switching, gas pressure, flow adjustable and equipped with flame temperature recognition device.
Flame standard | ANSI/ASTM D 5207 & UL 1581 |
Burner Tube | ANSI/ASTM D 5025 |
Burning Angle | 0°,20° |
Thermocouple | Type K (Ni/Cr - Ni/Al), 200°~1050 |
Thermocouple Size O/D | 0.5 mm |
Temperature Resolution | 1ºC |
Standard Copper Block | weight =10 ± 0 .05 g before drilling. Cu-ETP |
Time for Temperature to Increase | 1,225W/50mm(16.5mm)/84±2S A 405 ±10mL/min& 45±5 mm water 2,500W/125mm(40mm)/54±2S A 965 ±30mL/min&125±25 mm water B 385 ±15mL/min&552±100 mm water C 300 ±10mL/ min&600±125 mm water |
Gas Supply | methane, min.98% purity |
Input Power | 220 V 50 Hz 3A or 115 V 60HZ Optional |
Volume Of Chamber | >4m³, black interior |
Outer Dimensions | W*D*H=2000mm*1000mm*2000mm |
Conform to standard | UL1581 1060/1061/1080/1090/1100 |
Includes Flame height gauge and 100% absorbent cotton