Basic Info.
  • Brand Name: CONTEC 
  • display mode: parameter mode&waveform face 
  • Model No.: PM60E 
  • Place of Origin: Hebei  
  • Min.Order: 1 unit
Supply Capacity
  • Production Capacity: 50/weel
  • Delivery Date: 2 working days after payment id confirmed
Feature
PM60E base on the intellectualized opearating system flat,provide the analyse fuction of CO2 after the patient breath out, and provide accurate data and analyse report for you Performance

Specifications

■ Display: 3.5" TFT
■ Display mode: Parameter mode & Waveform face
■ Battery:
     Builtin Li-Polymer, 6 hours for charging , 3.7v,1900mah
     9 hours for continous working in the mode 1 or 2
     3 hours for continou working in the mode 3 or 4
     4 hours for continous working in the mode 5
■ Trend Graph/Table:
    Resolution from 1s, 5s, 10s,30s,1min,and so on. Storage of latest 96 hours
    trend data.
■ SpO2 drop analysis
■ History:
    Storage of latest 10000 case history in SD card.
■ Wave:
    Storage of 24 hours waveform, and only the real time stored patients have
     waveform
■ Alarm:
    Ajustable High and Low limits . Three level audible and visual alarm , latest
    50 alarm information and waveform displays 8 sec-onds which 4 seconds
    are before a certain time when the alarm is turned on and 4 seconds are
    after appointed time  when the alarm is turned on.

SPO2

■ Measurement Range: 0 ~ 100%
■ Resolution: 1%
■ Accuracy: ± 2 % (70% ~ 100% )
                         0% ~ 69% unspecified
■ Alarm Range: 0% ~ 100%
■ Refreshing Rate: 1s

Pulse Rate:

■ Measurement Range: 25 ~ 250 bpm
■ Alarm Range: 25 ~ 250 bmp
■ Resolution: 1bpm
■ Accuracy: ± 3 bpm
■ Refreshing Rate: 1s

ETCO2:

■ Measurement Range: 0 ~ 150 mmHg
■ Resolution: 0.1mmHg
■ Accuracy: ± 2mmHg
■ Alarm Range: 0 ~ 150 mmHg

AWRR:

■ Measurement Range: 0 ~ 150 bpm
■ Resolution: 1bpm
■ Accuracy: ± 1bpm
■ Alarm Range: 0~ 150bpm

Components

■ Main Unit                  
■ SpO2 Sensor
■ 1 G HIghSpeed SD Card
■ MicroStream EndTidal CO2 Module

Send message to this supplier
Ms. Chelsea Yang (Sales Manager)
Tel: 86-335-8015468
Enter between 20 to 3,000 chatacters.
Contact Method
Contec medical systems Co., Ltd
No.112 Qinhuang West Avenue,Economic and Technical Development Zone, Qinhuangdao, Hebei, China (Mainland) / 066000
Fax: 86-335-8015590
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center