STYD-2 Digital Display Asphalt Ductilometer
Application: Determination of ductility and the elastic reset of bitumen. Stainless steel for both casing and water bath.
Parameters:
1. Extension speed: 50±2.5mm/min
2. Max. ductility: 1500mm, 2000mm
3. Heating range: room temperature-50°C
4. Temperature accuracy: ±0.5°C
5. Voltage: AC220V 50HZ
6. Mould size: 75×32×10mm
7. Suitable for testing 3 samples simutaneously
8. Dimension: 2080×390×560mm
Features: Stainless steel for both inside and outside casing, with ABS controller, and twin lead screws