Technical Characteristics:
Compliant with GB4706.1-2005, IEC60335-1:2004, UL60335-1:2002, GB4943.1-2001, standard requirements
Three phase and single phase load are compatible; Three phase rated load capacity of 20kVA and custom 60kVA
Seven functions into one device: ground bond, insulation resistance, AC hipot, DC hipot, leakage current, power test and low voltage start test
15-group / 8-step test condition, intelligent judgment, auto compensation, auto protection; High speed test, the fastest speed can be 0.5s
Voltage ramp-up and ramp-down, discharge function; Dynamic and static leakage current, hipot test
Auto compensation, auto protection, auto memory, auto judgment, voice and light alarm
Serial communication, print, foot pedal interface, outer alarm light, PLC, network card interface
The precision is 2% for safety test; the precision is 5% for power test; Can support both grounding and suspending for DUT
Function preview, single screen setting, no need of flip, simple operation
Support both 50Hz and 60Hz frequency; Chinese and English operation interface
Compliant with GB4706.1-2005, IEC60335-1:2004, UL60335-1:2002, GB4943.1-2001, standard requirements
Three phase and single phase load are compatible; Three phase rated load capacity of 20kVA and custom 60kVA
Seven functions into one device: ground bond, insulation resistance, AC hipot, DC hipot, leakage current, power test and low voltage start test
15-group / 8-step test condition, intelligent judgment, auto compensation, auto protection; High speed test, the fastest speed can be 0.5s
Voltage ramp-up and ramp-down, discharge function; Dynamic and static leakage current, hipot test
Auto compensation, auto protection, auto memory, auto judgment, voice and light alarm
Serial communication, print, foot pedal interface, outer alarm light, PLC, network card interface
The precision is 2% for safety test; the precision is 5% for power test; Can support both grounding and suspending for DUT
Function preview, single screen setting, no need of flip, simple operation
Support both 50Hz and 60Hz frequency; Chinese and English operation interface
Model | AN9651TH (F)(Three Phase/Single Phase 7 in 1) | |
Ground Bond Test | ||
Empty Load Output Voltage | ||
Output Current Setting Range | AC 3A~30A 50Hz/60Hz, 1A/step | |
Output Current Setting Accuracy | ±(2% of setting+0.2A) | |
Upper Limit of Resistance | 3A≤Output current≤10A, 10~600mΩ; 10A | |
Ground Bond Resolution/ Measurement Range/ Accuracy | 1mΩ, 10~600mΩ, ±(2% of reading +2mΩ) | |
Compensation Resistance Measurement Range/Accuracy | 0~200mΩ 1mΩ | |
Test Time Setting Range | 0.5~999.9s 0.1s/step | |
Insulation Resistance Test | ||
Rated Output Load/Current | 1VA (1000V/1mA) 1mA | |
Output Voltage Range/Adjustable | DC:500V/1000V | |
Output Voltage Ripple | Pure resistance load, 1000V/1mA, | |
Output Voltage Accuracy/Resolution | ±(2% of setting+2V) 5V/step | |
Insulation Resistance Range | 1.0~2000MΩ | |
Insulation Resistance Lower Limit Setting Range/ Resolution | 1.0~99.9 MΩ, 0.1MΩ/step, 100~2000 MΩ 1 MΩ/step | |
Insulation Resistance Accuracy | 1~200 MΩ: ±(2% of reading+2counts), 200~2000 MΩ: ±(5% of reading+5counts) | |
Ramp-up Time Range/Resolution | 0.1~999.9s 0.1s | |
Delay Judgment Time | 0.3~10.0s (count from ramp-up ) | |
Test Time Setting Range | 0.5~999.9s 0.1s/step |