FC Series
- Designed for frequency inverters and variable speed motor drives
- Suitable for electronically noisy environments
- Protects programmable logic controllers from RF noise on the AC power line
- Side flanges for easy mounting
- Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications
Ordering Information
Available Part Numbers
6FC10 | |
12FC10 | 12FC10B |
16FC10 | 16FC10B |
25FC10 | 25FC10B |
36FC10 | 36FC10B |
50FC10 | 50FC10B |
Specifications
Maximum leakage current, each Line to Ground: | |||
B suffix | no suffix | ||
@ 120 VAC 60 Hz | 3.9 mA | 3.8 mA | |
@ 250 VAC 50 Hz | 6.8 mA | 6.7 mA | |
Hipot rating (one minute): | |||
Line to Ground | 2250 VDC | ||
Line to Line | 1450 VDC | ||
Operating Frequency: | 50 / 60 Hz | ||
Rated voltage (max.): | 250 VAC | ||
Rated Current: | 6A to 50A | ||
Operating Ambient Temperature Range (at rated current Ir): | |||
-10°C to +40°C | |||
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 |
Electrical Schematics
FC10
FC10B
Case Styles
6, 12, 16FC10
Typical Dimensions: | ||
Line/Load Terminals (4): | DIN type accepts 10AWG solid / 12AWG stranded | |
Ground Terminals (2): | 8-32 Torque 18 lbf-in. [2.03 N-m] max. ±2[..22] | |
Mounting Holes (4): | .203 x .156 [5.16 x 3.96] |
25, 36FC10
Typical Dimensions: | ||
Line/Load Terminals (4): | DIN type accepts 8AWG solid / 10AWG stranded | |
Ground Terminals (2): | 8-32 Torque 18 lbf-in. [2.03 N-m] max. ±2[..22] | |
Mounting Slots (4): | .260 [6.6] wide |
Case Dimensions
Part No. | A | B | C | D | E | F |
(max.) | (max.) | (max.) | ± .020 | (max.) | ± .010 | |
± .51 | ± .254 | |||||
6FC10 | 4.60 | 3.10 | 1.78 | 2.677 | 3.70 | 2.00 |
116.8 | 78.7 | 45.21 | 67.8 | 94.0 | 50.8 | |
12FC10/10B 16FC10/10B | 5.47 | 3.96 | 2.18 | 3.50 | 4.53 | 2.00 |
139.0 | 100.6 | 55.4 | 88.9 | 114.8 | 50.8 | |
25, 36, 50 FC10/FC10B | 7.10 | 5.48 | 2.55 | 4.90 | 5.94 | 2.756 |
180.3 | 139.2 | 64.77 | 124.5 | 150.9 | 70.0 | |
Performance Data
Typical Insertion Loss
Measured in closed 50 ohm system
6FC10
Typical Insertion Loss
Measured in closed 50 ohm system
6FC10
12FC10
12, 16FC10B
12, 16FC10B
Minimum Insertion Loss in dB
Measured in closed 50 ohm system
Common Mode / Asymmetrical (Line to Ground)
Part No. | Frequency - MHz | ||||||||
.01 | .03 | .05 | .1 | .5 | 1 | 5 | 10 | 30 | |
6FC10 | 9 | 19 | 26 | 37 | 65 | 65 | 50 | 40 | 35 |
12FC10 | 5 | 17 | 25 | 37 | 65 | 65 | 65 | 60 | 35 |
16FC10 | 4 | 15 | 22 | 36 | 65 | 65 | 70 | 70 | 35 |
25FC10 | 2 | 14 | 22 | 36 | 75 | 75 | 70 | 70 | 48 |
36, 50FC10 | - | 6 | 14 | 27 | 68 | 75 | 70 | 70 | 50 |
12, 16FC10B | 16 | 28 | 37 | 50 | 81 | 76 | 63 | 55 | 38 |
25FC10B | 14 | 25 | 36 | 49 | 91 | 88 | 71 | 64 | 46 |
36FC10B | 11 | 25 | 37 | 50 | 81 | 87 | 73 | 66 | 49 |
50FC10B | 11 | 24 | 36 | 49 | 81 | 75 | 62 | 54 | 37 |
Differential Mode / Symmetrical (Line to Line)
Part No. | Frequency - MHz | ||||||||
.01 | .03 | .05 | .1 | .5 | 1 | 5 | 10 | 30 | |
6FC10 | 10 | 10 | 35 | 60 | 75 | 75 | 60 | 50 | 45 |
12FC10 | 14 | 14 | 30 | 51 | 75 | 75 | 75 | 70 | 45 |
16FC10 | 14 | 14 | 29 | 55 | 75 | 75 | 75 | 70 | 45 |
25FC10 | 14 | 14 | 17 | 42 | 75 | 75 | 70 | 70 | 50 |
36, 50FC10 | 14 | 14 | 17 | 42 | 75 | 75 | 70 | 70 | 50 |
12, 16FC10B | 30 | 32 | 46 | 64 | 91 | 86 | 77 | 78 | 65 |
25FC10B | 24 | 24 | 31 | 46 | 92 | 87 | 86 | 75 | 55 |
36FC10B | 27 | 33 | 27 | 41 | 89 | 88 | 82 | 74 | 55 |
50FC10B | 30 | 32 | 48 | 64 | 91 | 87 | 82 | 79 | 67 |