VENTILATOR

Payment Terms: T/T or L/C AT SIGHT
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: LifeCare 
  • Certificate: CE,ISO,FDA 
  • Export Area: Europe,USA,Middle East,Asia 
  • Model No.: 600660© 
  • Place of Origin: Zhejiang  
  • Min.Order: 1 UNT
  • Means of Transport: By sea or by air
Supply Capacity
  • Packing:case
  • Delivery Date: 10days
MAIN FEATURE:

Be controlled by micro process.

Gas driven electronically controlled

Used for adult and pediatric

Color TFT display

English menu

PEEP function

End-inspiratory holding (inhalation platform, end-inhalation pause) function.

SIGH function

I/E function

Compliance compensated function.

Inspratory pressure and flow volume trigger function



MAIN TECHNICAL SPECIFICTION:

Mode: IPPV, IPPV+SIHG, A/C (SIPPV), SIMV, PCV, PSV SIMV+PSV, SPONT, MANU

Tidal volume: 50-1500ml

Frequency: 6-60/min

Inhalation time: 0.2-6s (I/E2:1-1:5)

Power :AC 22OV士10%,50 Hz士2%

Holding time: 0-3s

Controlling pressure: 1.0-6.0kpa

PSV level: 0-5.0kpa

PEEP/CPAP level: 0-0.2.kpa



Inhalation trigger: Pressue-0.2+2.0KPa. Flow volume 1-25L/min.

SIGH time: 1-5times (every 100 times)

Oxygen concentration: 21%-100 %( continual adjustable)

Ventilation Parameter monitoring: Tidal volume. Minute ventilation .frequency. Inhalation time. Airway Peak Pressure. PEEP. airway average Pressure,02 concentration. Time- airway Pressure waveform of dynamic Lung compliance。Time-flow waveform,trigger indicate and Pressure-volume loop.

Alarm:(Audio-visual) No tidal volume(asphyxia).minute ventilation 15 too high(low).airway Pressure is too high(low), Oxygen or air 15 not full. frequency is too high (when in SPONT),AC Power off. Back-up battery voltage is too low.

Power Off: There will be audio and Visual alarm indicates when Power is off in unusual way,and the Power w ill be supplied by back-up battery(battery working time≥3 hours).

Gas resource: oxygen or depurative air. The given working Pressure 15 0.4士0.IMPa. 600661A
with Air compressor.

Send message to this supplier
Mr. David Hee
Tel: 86-574-87255354
Enter between 20 to 3,000 chatacters.
Contact Method
Lifecare Medical Equipments Co., Ltd.
King International Building, NO.345, Huancheng West Road, Ningbo, Zhejiang, China (Mainland) / 315000
Fax: 86-574-87125894
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center