Lifecare Medical Equipments Co., Limited is an international shareholding company well known as a professional exporter of medical equipments and systems that contribute to quality enhancement and cost efficiency within health care and life sciences. We have consistently provided solutions to various markets and application needs and offer a wide range of ... view more
Company Profile
Annual Sales Amount:
US$2.5 – 5 Million
Export Ratio:
71% – 80%
OEM Services Provided:
NO
Payment Terms:
T/T, D/P, WU, Paypal
Business Type:
Manufacturer, Trading Company
Quality Certificate:
CE, ISO9001, ISO9000, ISO14000, FDA, RoHS
Main Export Markets:
North America, Western Europe, Eastern Europe, South America, Southeast Asia, Eastern Asia, Mid East, Oceania, Africa
Basic Info.
Brand Name:LifeCare
Function:MEDICAL USE
Certificate:CE .ISO9001,13485
Export Area:EUROPE /ASIA /MIDDLE EAST
Model No.:601173
Place of Origin: Zhejiang
Min.Order: 1 UNIT
Means of Transport:BY SEA /BY AIR
Supply Capacity
Packing:CASE
Delivery Date:10DAYS
Specifications
Performance ● Applies to operating room and ICU/CCU rooms
● Can monitor adults、children and infants
● Monitoring items: ECG、heart rate、respiration rate、SpO2、pulse、temperature、NIBP、end-tidal carbon dioxide
● Printer is optional ECG ◇ Method of measurement : 25bpm~230bpm
◇ Measurement error: ≤±5%
◇ Lead: seven leads
◇ Gain: ×0.5, ×1, ×2,
◇ Alarm range: Upper limit : 30bpm~230bpm
Lower limit: 20bpm~120bpm SpO2
◇ Method of measurement :60%~99%
◇ Resolution: 1%
◇ Measurement error: ≤±2% (90%~99%)
≤±4% (70%~89%)
≤±6% (60%~69%)
◇ Alarm range: Upper limit : 70%~99%
Lower limit: 60%~98% Respiration
◇ Method of measurement: chest impedance
◇ Measuring range: 6bpm~60bpm
◇ Alarm range: upper limit : 30bpm~60bpm
Lower limit : 6bpm~40bpm Temperature
◇ Measuring range: 34.0℃~43.0℃
◇ Measurement error: ≤±1℃
◇ Resolution: ± 0.1℃
◇ Alarm range:
Upper limit: 36℃~43℃ Lower limit: 34℃~36℃ NIBP
◇ Method of measurement : automatic surging method
◇ Working mode: manual/auto
◇ Interval of auto measuring mode: 1、2、5、10、15、20、30、45、60、90、120、150、180、210、240(min)
◇ Measuring range:
Systolic pressure: 50mmHg~240mmHg
Mean pressure: 26mmHg~200mmHg
Diastolic pressure: 22mmHg~180mmHg
◇ Alarm range:
Systolic pressure: Upper limit: 48mmHg~240mmHg
Lower limit: 46mmHg~238mmHg
Mean pressure: Upper limit: 26mmHg~200mmHg
Lower limit: 24mmHg~198mmHg
Diastolic pressure: Upper limit : 22mmHg~180mmHg
Lower limit: 20mmHg~178mmHg End-tidal CO2
◇ Measuring range: 0kPa~10kPa(0mmHg~75mmHg)
◇ Measurement error: ±0.3kPa(0kPa~5.4kPa)
±0.7kPa(5.5kPa~10.0kPa)
◇ Alarm range: Upper limit 0.2kPa~10.0kPa
Lower limit 0kPa~9.8kPa Alarm
◇ the monitor can set alarm for all monitoring parameters, it can set the alarm with sound and light. It can also cancel the alarm Others: ◇ Power supply: AC 220V±10%,50Hz±1Hz
◇ Power: 80VA
◇ Display: CRT display
◇ Working condition: temperature: 5℃~40℃
◇ Relative humidity: ≤85%
◇ Atmospheric pressure:86kPa~106kPa
Send message to this supplier