12" portable modular multi-parameter Patient Monitor

Payment Terms: T/T,L/C;PayPal
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: NCC 
  • Application: Neonatal, pediatric & adult 
  • Design: Flexible 6-parameter module 
  • Model No.: X3 
  • Place of Origin: Shanghai  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Air
Supply Capacity
  • Production Capacity: 100 sets per week
  • Packing:260*410*530 mm
  • Delivery Date: 3-5 working days

 Features

1. Modular designwith higher integration, more stable functions, and lower power consumption,easy to replace

2. 12inch high definition color TFT display

3. AC/DCavailable, suitable for ward bedsides, ICU care and Operating Room

4. Standardsix-parameter module: ECG, HR, NIBP, SpO2, RESP and TEMP

5. Monitor andanalysis: arrhythmia analysis, ST segment analysis, drug concentration andtitration table calculation

6. NIBPmeasurement using a double overpressure protection technology to prevent injuryfrom high inflation pressure

7. 720hours of trend data playback, 2 hours of waves playback, up to 1000 BP review,up to 200 alarm events review

8. 3-levelintelligent alarms: sound, light and voice alert, volume adjustable

9. Supportwired networking, support mixed network connection


ECG

Lead type: 3/5 leads electric cable

Input: 3 leads: RA, LA, LL (Lead method: I, II, III)

            5 leads: RA, LA, LL, RL, V (Lead method: I, II, III, aVR, aVL, aVF, V)

Heart rate range: 15~300bpm (adult), 15~350bpm (child & neonate)

Accuracy: ±1bpm or ±1%, whichever is bigger

ST detection: Range: -2.0mV~ +2.0mV, Accuracy: -0.8 mV~ +0.8mV

Arrhythmia analysis: 13 kinds


NIBP (Noninvasive blood pressure)

Method: Pulse wave oscillation

Operation mode: Manual/Automatic/Continuous

Time interval (Automatic):1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480mins

Time interval (Continuous): 5mins

Range:Adult: Systolic blood pressure: 40~280mmHg

                        Diastolic blood pressure: 10~220mmHg

                        Mean pressure: 20~240mmHg

              Child: Systolic blood pressure: 40~220mmHg

                        Diastolic blood pressure: 10~160mmHg

                        Mean pressure: 20~170mmHg

         Neonate: Systolic blood pressure: 40~135mmHg

                       Diastolic blood pressure: 10~100mmHg

                       Mean pressure: 20~110mmHg


SpO2 (finger pulse oximetry)

Range: 0~100%

Resolution: 1%

Accuracy: ±1% (70~100%), ±2% (40%~69%), not defined (<39%)


Respiration

Method: RA-LL impedance

Range of respiratory impedance: 0.3~3 ohm

Respiration rate:7~120BrPM (adult), 7~150BrPM (child & neonate)


Temperature

Sensor type: 10K series, 2.25K series

Channels: dual channels


Send message to this supplier
Mr. Kent Zhang (Sales Representative)
Tel: 86-21-51029700
Enter between 20 to 3,000 chatacters.
Contact Method
NCC MEDICAL CO., LTD
940 Jianchuan Road, Shanghai, China (Mainland) / 200240
Fax: 86-21-51029700
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center