Used for first aid, ambulance and patients transport within hospital,
it can be used for pediatric and adult patients.
use for first aid, use for ambulance, use for patients transport ,within hospital
Physical Specifications
Ventilator Dimensions
Width: 300mm Depth: 140mm Height: 230mm
Carrying packages Dimensions
Width: 460mm Depth: 160mm Height: 350mm
Packaging Dimensions
Width: 620mm Depth: 410mm Height: 240mm
Ventilator Weight:3Kg
Carry bag Weight (with cylinder ): 7Kg
Packaging Weight: 11Kg
Environmental Specifications
Operating Requirements
Temperature: 5 to 40 ℃ ;
Relative Humidity: less than 80%;
The atmosphere pressure: 70 to 106 kPa ;
Storage/Shipping Requirements
Temperature: -20 to 70 ℃
Relative Humidity: less than 93%
The atmosphere pressure: 70 to 106 kPa
Electrical Specifications
Internal battery DC12V 2200mA
Input Power Supply Requirements
DC 12V 10 VA;
Charger Power Supply Requirements
AC 220V+/-15% 50HZ+/-2% 25 VA;
Pneumatic Specifications
Oxygen Inlet Pressurized Oxygen: 0.4 MPa ±10% medical oxygen(Availability through Oxygen Pressure Reducer provided as a accessory)
What Is Provided
Parts Name | Number | Specification |
Ventilator | 1 | |
Oxygen Cylinder | 1 | 2.5L can be used for 1 hour |
Carry bag | 1 | With cylinder |
Breath Circuit | 1 | 1.2m |
Breath Value | 1 | |
Mask | 1 | |
Chargers | 1 | |
Battery | 1 | Can be used for 8 hours |
Wrench Tool | 1 | |
Oxygen Pressure Reducer | 1 | For Normal Oxygen Cylinder |
Oxygen Bridge | 1 | |
Hand Book | 1 | |
CD For Operation | 1 |
Performance Specification And Tolerances
Ventilator Parameters | Ranges | Remark |
Controls | ||
Power | ON/OFF | |
Modes CMV(IPPV) A/C(SIPPV) SIMV SPONT PEEP(Choice for suppliers) | ||
Tidal Volume | 50~1200ml | |
Breath Rate | 5~60 bpm 1~12 bpm for SIMV | |
Sigh | 1~10 per 100 breath | |
%O2 | 45~90% | |
Trigger Level | -10~0hpa | |
PIP | 0~60hpa | |
Base Flow | 0~5L/min | |
Peep | 0~10 hpa | (Choice of suppliers) |
Over Pressure Relief | < 60hpa |
Performance Specification And Tolerances
Ventilator Parameters | Ranges | Tolerances |
Alarms and Indicators | ||
High Pressure Alarm Limit | 20~60hpa to be set flash, red indicator | +/-0.1kpa |
Low Pressure Alarm Limit | 2~20hpa to be set Red indicator | +/-0.1kpa |
Low Battery Voltage | Surplus energy can work for an hour red indicator | |
Alarm | Red indicator | |
Alarm Silence | Yellow indicator | 120s |
Power | Green indicator | |
Charging Indicator | Green indicator |
Performance Specification And Tolerances
Ventilator Parameters | Ranges | Remark |
Monitors | ||
Main Circuit Pressure | -20~100hPa | |
Wave Display | ||
Main Circuit Pressure |