SAT003 BSC-1000IIA2 Class II Bio Safety Cabinet

Trade Term: FOB
Payment Terms: T/T,
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: AIRTECH 
  • Cleanliness: ISO Class 5,Class 100(Fed 209E) 
  • Model No.: BSC-1000IIA2 
  • Place of Origin: Jiangsu  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean
Supply Capacity
  • Production Capacity: 50
  • Packing:wood
  • Delivery Date: 15
 Characteristics
1.Approved by YY0569 of Chinese SFDAClass II,
Type A2 Biological Safety Cabinet of AmericanNSF/ANSI49
2.Vertical lamina airflow, 70% air circulation, 30% airexhaust.
3.HEPA and ULPA with NO LEAKING(Patent No.ZL200820109130.9)inair
supply and exhaust system, ensure the cleanliness of ISO Class 5 (Class100)
or ISO Class 4(Class 10)
4.Negative pressure and double layersChamber with SUS work area.
5.The viewscreen of gradient of 10 make itcomfortable to operate.
6.Demoutable circular-arc shelf can alieviate workingtiredness and make it
easy to transport.
7.Non-obstructive air return modein the front suction channel(Patent No.ZL200520140353.8).
8.Touchable controlpanel and LCD,flow indicator and waming.
9.Photoelectric alarm for slidingdoor and light.
10.Interlocked light and sterilizing.
11.Anti-splashsafety spare socket and junction valve.
12.Intelligent auto-supply systemensures the change of air volume less
than 10% when the resistance of filterincreases 50% and enhance safety.
13.Leak detection in cabinet, no leakage at500Pa.
14.Leak detection in HEPA/ULPA, leaking ratio is<=0.01%
(scanned), <=0.005%(not scanned).
Model andItemBSC-1000 IIA2
CleanlinessHEPA:ISO5(Class 100)/ULPA:ISO4(Class 10)
FiltrationEfficiencyHEPA:>=99.995%,@0.3 μm/ULPA:>=99.999%,@0.12 μm
DownflowVelocity0.35
InflowVelocity0.55
Noise<=58
PowerSupply~220V,50Hz
OperatorProtection
a.Total colony in impaction sampler<=10CFU./time
b.Total colony in slot sampler<= 5CFU./time
ProductProtectionTotal colony in culture dish<=5CFU./time
CrossContaminationTotal colony in cultere dish<=2CFU./time
Power(with sparesocket)2.0
Weight260
WorkDimension970*600*620
OverallDimension1200*790*2050
Size and Qty. ofLight36*2
Size and Qty. of UVLight20*1
Lumin.>=800
AirDirectionTop out

Send message to this supplier
Mr. Henry Yu (sales)
Tel: 86-512-65319409
Enter between 20 to 3,000 chatacters.
Contact Method
Suzhou Antai Airtech Co., Ltd
No. 2, Weixin Road, Suzhou, Jiangsu, China (Mainland) / 215122
Fax: 86-512-65520020
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center