Furnace wall water-cooled wall tube in furnace export smoke window Department is pulled into two row, it constitutes coagulation slag bundle with boiler bundle.Flue gas through a baffle lateral scour convection tube from the bottom up. After cooling ,flue gas enter the boiler tail flue, scour tail-heating surface, through iron coal saver and air pre-heater, and then discharge furnace, into the dust collector, finally from chimneys into the atmosphere.
SHW Series Field Assemble Reciprocating Grate Steam Boiler combustion equipment adopts reciprocating grate. Due to the moving grate push feed, It can mix the burning and unburned fuels, it is greater grate ignited. Grate the push feed also play the flames .Because fuel particle wipe ,the outer layer of ash in coke-start fall off, the movable grate in while feeding also crush cinder blocks, which can make fuel better burn. It is a simple structure, convenient, smoke effects, smoke and low dust content.
SHW Series Field Assemble Reciprocating Grate Steam Boiler adopts balanced ventilation blowers and induced draft fans mode, it maintains negative combustion pressure 20Pa in the furnace, it is under negative pressure in the flue,it is conducive to environmental health.
We take the example of SHW15-1.25-H ,SHW Series Field Assemble Reciprocating Grate Steam Boiler. The design of boiler parameters:
()rated evaporation capacity: 15t/h
()rated steam pressure: 1.25MPa
()rated steam temperature: 194°C
()feed water temperature: 105°C
()air temperature: 30°C
()flue gas temperature: 132 ℃
()discharge rate: 5%