Ultra High Voltage 500kv Underground High Voltage Power Cable 1 * 1000mm 

 

 

Quick Detail:

 

Insulation Material

XLPE

Type

High Voltage

Application

Underground

Conductor Material

Copper

Jacket

PVC

Character

waterblock

 

Description:

 

   XLPE-insulated power cables for rated voltage 110kV should perform the rules of XLPE-

insulated Power Cable for Cable for Rated Voltage 110kV and its attachments in GB/T 11017-

2002, which is equal to The Test Methods and Requirements of Extruded Insulation Power

Cables for Voltage 30kV up to 150kV in IEC 60840:1999.


   XLPE-insulated power cables for rated voltage 220kV should perform the rules of XLPE-

insulated Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 18890-

2002, which is equal to The Test Methods and Requirements of Extruded Insulation Power

Cables for Voltage 150kV up to 500kV in IEC 62067:2001.


XLPE-insulated power cables for rated voltage 500kV should perform the rules of XLPE-

insulated Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 22078-

2008, which is equal to The Test Methods and Requirements of Extruded Insulation Power

Cables for Voltage 150kV up to 500kV in IEC 62067:2006.


XLPE-insulated power cables for rated voltage 66kV should perform The Test Methods and

Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC

60840:1999.

 


Main Performance


1.The rated voltage U0/U of cables:38/66kV, 48/66kV, max. voltage Um=72.5kV;
                                 64/110kV, max. voltage Um=126kV;
                                127/220kV, max voltage Um=252kV;
                                 290/500kV, max voltage Um=550kV;
2. permissible long-term working temperature of cable conductor:90;

3. When the cable confronts short circuit within 5 seconds, the highest temperature of

   conductor should not exceed 250. When there exits line joints, the temperature of tin

   soldering ones should not exceed 120, the temperature of crimping ones should not exceed

   150, and the temperature of electric or gas welding should not exceed 250

4. When laying, the permissible bending radius should exceed 25 times of the out diameter of

    the cables.After laying, the permissible bending radius should exceed 23 times of the out

    diameter of the cables.

       1.When laying, ambient temperature≥0(when the cable has to be laid under the ambient

           temperature below 0,it is necessary to preheat the cable above 0)

       2.When laying, the cable is not limited by disparity with the satisfaction of mechanical

           pressure, but it is not permissible to lay the cable in the iron pipe, nor the circular iron

           materials around fixed cables.

 

 

Applications:

 

the type, name, and suitable areas

type

 

Description

 

Suitable for

Copper-conductor

AL-conductor

YJV,YJY

YJLV, YJLY

XLPE insulated PVC/PE 

sheathed power cable

Installation in the tube, 

channel or in air,

resistant certain tension

Send message to this supplier
Ms. Wang
Tel: 86-0374-2795966
Enter between 20 to 3,000 chatacters.
Contact Method
Henan Xuchang Sunlight Electric and Optical Cables & Wires Co., Ltd.
Sunlight Block, Electric and Technology Development District, Xuchang, Henan, China (Mainland)
Related Products
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!