2ft 10W LED Emergency T8 Tube Light(external driver)

skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

Product name:2ft 10W Emergency T8 Tube Light(external driver)

Model:ZS-T8E-2835

Features:

  • Led type: Epistar SMD2835

  • External isolated driver

  • Duration Time: 3 hours

  • Charging Time: 3 hours

 

Driver:

---drive of 10W LED Emergency T8 Tube Light

 

General specification:

Power

Dimension

LED Qty

Lumen

3-10W

Φ28mm*L600mm

48pcs

285lm~950lm

3-20W

Φ28mm*L1200mm

96pcs

285lm~1900lm

3-25W

Φ28mm*L1500mm

120pcs

285lm~2375lm

3-30W

Φ28mm*L1800mm

144pcs

285lm~2850lm

Emergency: 3W

Emergency: 285lm

Color Temperature: 3000K/4000K/6000K

CRI: 72Ra

Power Factor: 0.95

Input Voltage: AC 100-240V

View Angle: 145° 

Working Temperature: -20℃-45℃

Output Voltage: 30-39V

Output Current: 70mA

Input Power: 3.5W/Max

Output Voltage(Battery Charging): DC 4.7-8.4V

Charging Current: 275mA

Power Efficacy: 70%

 

Dimmension:

---Dimmension of LED Emergency T8 Tube Light

 

Dimensions:

Product

LED tube 600mm

LED tube 1200mm

LED tube 1500mm

LED tube 1800mm

Emergency Driver

Diameter

28mm

28mm

28mm

28mm

40mm

Length

588mm

1198mm

1498mm

1763mm

222mm

 

Driver size:

---driver size of LED Emergency T8 Tube Light

 

Electrical Parameter:

LED Tube

State

Power

Input

Voltage

Power

Efficiency

Power

Factor

THD

PFC

Output

Accuracy

600mm

City Electricity

10W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

1200mm

City Electricity

20W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

1500mm

City Electricity

25W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

1800mm

City Electricity

30W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

Optical Parameters:

LED Tube

State

Luminous flux

Efficiency

Illuminance

600mm

City Electricity

880lm

88lm/W

1m

2m

3m

Emergency

250lm

83lm/W

201lux

47lux

21lux

1200mm

City Electricity

1800lm

90lm/W

39lux

12lux

6lux

Emergency

250lm

83lm/W

312lux

87lux

42lux

1500mm

City Electricity

2250lm

90lm/W

30lux

8lux

4lux

Emergency

250lm

83lm/W

361lux

113lux

54lux

1800mm

City Electricity

2850lm

95lm/W

27lux

6lux

2lux

Emergency

250lm

83lm/W

416lux

137lux

66lux

(All the figures are tested by the tube of daylight (6000K).

 

Emergency LED T8 tube lights are designed for unexpected situation, which can maintain lighting with battery when the city electricity is off suddenly. Also, they can work as normal lighting source and supply enough light in daily work and life.

  • Super bright LED tube with emergency function;

  • Input voltage: AC 100-240V;

  • Duration time: 3 hours;

  • Emergency mode power: 3W;

  • Operating temperature: -20℃~45℃;

  • IP42 protection rating;

  • ≥36000 hours life span;

  • 2 years warranty

 

Wiring diagram:

---wiring diagram of LED Emergency T8 Tube Light

 

Emergency Driver: Except for normal lighting, emergency LED T8 tube light has a rechargeable lithium battery in the external driver, which is used for emergency lighting. For showing operating state, there are three indicators on it.  

Red indicator: On—–charging

                          Off—– charged

Yellow indicator: On—–System failure

                               Off—–Working

Green indicator: On—–electricity supply

                              Off—–electricity disconnected

 

---driver of LED Emergency T8 Tube Light

 

Indicating Wire: In order to inform the working state of emergency driver more conveniently, indicating wire is available, which is inserted on the end of driver. The switch is used for emergency function test, and the purpose of red, yellow and green indicators is the same as the three indicators on the driver.

 

Indicating wire:

 

---indicating wire of LED emergency T8 Tube Light

 

Function:

The emergency LED T8 tube light can switch automatically between normal lighting and emergency lighting. If there is no city electricity, the battery will be in operation. Two modes are available:  

City electricity mode: When the city electricity is connected, the LED tube can work as normal lighting for daily life. The battery in external emergency driver is being charged automatically.

Emergency mode: If the city electricity fails, the battery will work and supply power to the LED tube for lighting. And the emergency lighting can last for 3 hours. Perfect protection is applied for the battery when voltage is low and short circuit happens.

 

Installation:

  • Switch off the power of mains supply and respectively of the connection lead before installation to avoid electrical shock;

  • Emergency LED tube is fixed in the light fixture same as the normal LED tube;

  • Use screw to fasten the emergency driver on flat place;

  • Switch wire is connected to L, and AC 100-240V city electricity supply power to L and N;

  • The product is used indoor only and kept away from direct sunshine and high temperature.

 

---installation of LED Emergency T8 Tube Light

 

---installation of LED Emergency T8 Tube Light

 

Packaging:

Length

Outer Carton size

(L*W*H)

Qty/Carton

N.W.

G.W.

600mm LED tube

645x265x218mm

20pcs

6.50kg

7.00kg

1200mm LED tube

1260x265x218mm

20pcs

11.30kg

12.60kg

1500mm LED tube

1570x265x218mm

20pcs

15.20kg

16.00kg

1800mm LED tube

1830x265x218mm

20pcs

19.2kg

20.4kg

Emergency driver

580x260x210mm

40pcs

13.6kg

15.00kg

 


Send message to this supplier
Ms. Roya (sales Manager)
Tel: 86-574-89101869
Enter between 20 to 3,000 chatacters.
Contact Method
ZheJiang Sino-World Import & Export Co., Ltd
Room#906, Rong an Building, No 659, QianHu Road Yinzhou, Ningbo, Zhejiang, China (Mainland) / 315140
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center