A) Without build-in water pump and heat exchanger | |||||
Model | TYNRB-15 | TYNRB-20 | TYNRB-35 | TYNRB-50 | TYNRB-200 |
Power | ~220V 50/60HZ | 380V 50/60HZ | |||
Rated water output temperature(℃) | 55 | ||||
Maximum water output temperature(℃) | 65 | ||||
Rated heat capacity(W) | 1600 | 2000 | 3500 | 4500 | 20000 |
Rated power input(W) | 320 | 370 | 680 | 800 | 5000 |
Rated current input(A) | 1.4 | 1.7 | 3.1 | 3.7 | 7.5 |
Noise (dB(A)) | ≤45 | ≤60 | |||
Weight(Kg) | 18 | 20 | 23 | 26 | 80 |
Size(L*W*Hmm) | 325X225X400 | 325X225X400 | 380X280X440 | 500X400X600 | |
Water tank capacity L | 100,150 | 150,200 | 200,300 | 300,500 | 2000 |
Applicable enviroment temperature(℃) | –20~45 | ||||
Thermodynamic solar panel quantity | 1pc | 1pc | 1pc | 2pcs | 16pcs |
B) With build-in water pump and heat exchanger | |||||
Model | TYN-15 | TYN-20 | TYN-25 | TYN-35 | TYN-50 |
Power | ~220V 50/60HZ | ~220V 50/60HZ | ~220V 50/60HZ | ||
Rated water output temperature(℃) | 55 | 55 | 55 | ||
Maximum water output temperature(℃) | 65 | 65 | 65 | ||
Rated heat capacity(W) | 1600 | 2000 | 4500 | ||
Rated power input(W) | 320 | 370 | 800 | ||
Rated current input(A) | 1.4 | 1.7 | 3.7 | ||
Noise (dB(A)) | ≤45 | ≤45 | ≤45 | ||
Weight(Kg) | 18 | 20 | 26 | ||
Size(L*W*Hmm) | 380X450X450 | 380X450X450 | 400X480X480 | ||
Water tank capacity L | 100,150 | 150,200 | 300,500 | ||
Applicable enviroment temperature(℃) | –20~45 | ||||
Thermodynamic solar panel quantity | |||||
Model | TYN-70 | TYN-85 | |||
Power | |||||
Rated water output temperature(℃) | |||||
Maximum water output temperature(℃) | |||||
Rated heat capacity(W) | |||||
Rated power input(W) | |||||
Rated current input(A) | |||||
Noise (dB(A)) | |||||
Weight(Kg) | |||||
Size(L*W*Hmm) | |||||
Water tank capacity L | |||||
Applicable enviroment temperature(℃) | |||||
Thermodynamic solar panel quantity | |||||
C) Commercial use with build-in water pump and heat exchanger | |||||
Model | TYN-120 | TYN-300 | |||
Power | ~380V 50/60HZ | ~380V 50/60HZ | |||
Rated water output temperature(℃) | 55 | 55 | |||
Maximum water output temperature(℃) | 65 | 65 | |||
Rated heat capacity(W) | 12000 | 30000 | |||
Rated power input(W) | 3000 | 7500 | |||
Rated current input(A) | 4.5 | 11.6 | |||
Noise (dB(A)) | ≤55 | ≤60 | |||
Weight(Kg) | 100 | 180 | |||
Size(L*W*Hmm) | 800X500X800 | 1000X600X1000 | |||
Hot water flow rate(L/H) | 700 | 1400 | |||
Pipe connecting thread | G3/4" | G1-1/4" | |||
Applicable enviroment temperature(℃) | –20~50 | ||||
Thermodynamic solar panel |