Single / Three Phase Current Transformer Test Equipment For Auto Test Error

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

Single / Three Phase Current Transformer Test Equipment For Auto Test Error

 

The product could do the test of three phase combined transformers, at the same time it can provide three phase test voltage and current for the three phase combined transformer. Frequency and phase of the voltage and current could be adjusted

 

 

Highlight:

  • Auto test of the error, auto saving of the error, and auto rounding of the error
  • Adopt 320×240 matrix LCD, large active area, with long life back lightning.
  • Auto sampling according to the requirements of the JJG314-1993 and JJG314-1994
  • Auto detect the polarity and transformation ratio mistake, and auto change of the range
  • Automatic and manual operation
  • It makes the paperless operation possible from testing to the report printing and the certification of inspection with PC software.
  • The system could monitor the current and the voltage, and it also has the function of positive and negative going motion interlocking, rotation limitation and protection.
  • Under the rating power, the distortion factor of the voltage and the current: ≤1%, the output is stable and the point sort is quick and convenient.
  • The output adjustment accuracy 0.5‰, which solves the problem of the point 1.0% that is difficult to adjust in CT measuring.

 

 

Main specifications:

 

Voltage output

Output range

Simultaneous output the 20%120% of the primary voltage of the voltage transformer (VT), it is continuous and adjustable

Output power of voltage

Single phase: 0~120V  power output:1×1kVA

Three phase three wire(V type):0~240V, power output:2×1kVA

Three phase four wire(Y-type):0~240V, power output:3×1kVA

Current output

Output range

Simultaneous output the 1%120% of the primary current of the current transformer (CT), it is continuous and adjustable

Output power of current

Three phase six wire:0~240V, power output:3×2kVA

Frequency output

Output range

45~65Hz,(fundamental frequency)continuous and adjustable

Operation conditions

Power supply

220V±10%  50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

35% -- 85%RH


Send message to this supplier
Mr. Vivi Zhang
Tel: 86-20-62220181
Enter between 20 to 3,000 chatacters.
Contact Method
Guangzhou Kingrise Enterprises Co.,LTD.
Rm 210, No 69 Guangpu Rd(W), Luogang Dist, Guangzhou, Guangdong, China (Mainland)
Related Products
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center