Quick Details

  • Type: First-Aid Devices
  • Brand Name: Jumper
  • Model Number: JPD-800B
  • Place of Origin: Guangdong, China (Mainland)
  • Standard parameters: ECG,SPO2,RESP,TEMP,NIBP.PR
  • Option: printing,IBP,VGA,EtCO2,Touch screen
  • Certificate: CE&ISO
  • Warrenty: 1 year
  • Display:: 12.1" TFT color screen
  • central monitoring system:: available
  • data storage:: Maximum 720 hour
  • Power supply: 100~250 (V)AC, 50/60 (Hz)
  • Net weight:: 6.5kg
  • Dimension:: 40*25*47.5cm

General instruction:

 

Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.  

 

Specifications

 

ECG

Lead mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection I, II, III, avR, avL, avF, V,

Waveform 2 ch

Lead mode 3 Leads ( R, L, F or RA, LA, LL)

Lead selection I, II, III,

Waveform 1 ch

Gain: X2.5mm/mV, X5.0mm/mV, X10mm/mV, X20mm/mV, auto

Resolution 1 bpm

Sensitivity > 200 (uV P-P)

Differential Input Impedance > 5 MΩ

CMRR

Monitor > 105 dB

Operation > 105 dB

Diagnosis > 85 dB

Electrode offset potential 300mV

Leakage Current < 10 uA

Baseline Recovery < 3 S After Defi.

ECG Signal Range: 8 m V ( Vp-p )

Bandwidth

Surgery 1 ~ 15 Hz

Monitor 0.5 ~ 35 Hz

Diagnostic 0.05 ~ 100 Hz

5%±Calibration Signal 1 (mV p-p), Accuracy :

ST Segment Monitoring Range

Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

 

Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R

ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm Available

Review Available

 

RESP

Method Impedance between R-F(RA-LL)

Differential Input Impedance >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 ~ 2.5 KΩ

Bandwidth 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

Adult 0 ~ 120 rpm

Neo/Ped 0 ~ 150 rpm

Resolution 1 rpm

Accuracy  2 rpm

Apean Alarm 10 ~ 40 S

 

NIBP

Method Oscillometric