Current Transformer Power transformer Full Projects Testing Device

Price: 1000.0~2000.0 USD
Trade Term: FOB
Payment Terms: T/T,L/C,D/A
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: GOLD 
  • Model No.: GDVA-404 
  • Place of Origin: Chongqing  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Packing:wooden case
  • Delivery Date: 15 days after accepting down payment

GDVA-404 CT/PT Tester

1 Application

Test for current transformer (ct)

1)Excitation curve and parameters test

2)Turns ratio test

3)Ratio and phase error test

4)Polarity mark check

5)Coil resistance measurement

6)Secondary loop burden measurement

7)Error line curve test for protection CT

8)Transient CT parameters test

9)CT nameplate guess

Tests for power transformer(pt):

1)Excitation curve test

2)Turns ratio test

3)Polarity test

4) Secondary burden test

5) Coil resistance test

Applications for current transformer CT powertransformer PT analyzer:

1) CT nameplate check

2) CT parameters check in work burden

3) CT transient parameters analysis

4) CT ratio and phase error calibration

5) PT routine test

1.2 CT PT analyzer technical index

Test standards

 

IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13

 

Power supply

AC220V±10%,50Hz/60Hz±10%

Power output

0.1~125V (AC)

Current output

 

0.001~5A(RMS)

Power output

300VA

Current output

0.001~5A(RMS)

Power output

300VA

Current measurement

Range:0~10A (automatically change range in 0.1/0.4/2/10A) 

Error <±0.1%+0.01%FS

 

Voltage measurement

Range:0~200 V (automatically change range in 1V/10V/70V/200V)

Error < ±0.1%+0.01%FS

 

Turns ratio measurement

Range :1~10000,

1~1000 error<0.05%

1000~2000 error<0.1%

2000~10000 error<0.2%

 

Phase measurement: 

error:±2min,resolution:0.01min

Coil resistance measurement

Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)

Error< 0.1%+0.01%FS

 

Turns ratio measurement

Range :1~10000,

1~1000 error<0.05%

1000~2000 error<0.1%

2000~10000 error<0.2%

 

Phase measurement

error:±2min,resolution:0.01min

Coil resistance measurement

Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)

Error< 0.1%+0.01%FS

Maximum resolution:0.1mΩ

 

Temperature measurement

 

-50~100 Celsius degree, error<3 Celsius degree

 

CT Secondary burden: 

 

Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)

Error <0.1%+0.01ohm

PT Secondary burden: 

 

Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)

Error <0.2%+0.02%FS 

Maximum resolution: 0.1ohm

 

Saved data groups

 

>1000groups

 

Work condition: Temperature

-10℃~50℃, moist:≤90%

Size: 

 

 

485mm×356mm×183mm  <13Kg

 

Related Products:

GDVA-401 CT/PT Tester

GDVA-402 CT/PT Tester

GDVA-403 CT Tester



Send message to this supplier
Mr. lu
Tel: 86-23-62940053
Enter between 20 to 3,000 chatacters.
Contact Method
chongqing gold mechanical and electrical equipment co.,ltd
9F/10 Jintai building nanping street nanan district, Chongqing, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center