LED Display Syringe Pump Medical Vacuum Pumps For Hospital

 

Quick Detail:

 

Compatible Syringe: Any standard syringe with 5ml, 10ml, 20ml, 30ml, 50ml and 60ml.

 

 

Description:

 

1. Four working modes:
Rate mode, Time mode, Weight mode and Drug mode
2. 174 Drugs with 10 Categories of Drug Library
Cardiovascular Sys, Respiratory Sys, Antibiotics Sys, Alimentary Sys.
Nervous Sys, Analgesic Sys, Urinary Sys, Blood Sys, Endocrine Sys.
17 units of dose: Ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, IU/h, U/kg/h, ng/kg/min, can make drug dispensing more convenient and safer.
3. ICU infusion workstation: Combines for syringe pumps and one infusion
Pump with Infusion Support into one ICU Infusion Workstation, sharing a Power Interface.
4. Stackable up to the maximum 8 channels. Transfer the message between the Nurse-call System and the pumps.
5. Bolus Function.

 

Multi-channels Syringe Pump JAZ-1800C

Model specification

JAZ-1800C

Flow rate(ml/h)

50ml: 0.1-1800ml/h   20ml: 0.1-800ml/h 10ml: 0.1-400ml/h 5ml: 0.1-200ml/h any standard syringes are available

Time mode

SOL. VOL.: 0.1-999.9ml (0.1ml step) Running Time: 1-1999min (1min step)

Body weight mode

SOL. VOL.:   0.1  - 999.9mg (0.1mg step)
Drug Mass   0.1  - 999.9ml (0.1ml step)
Dose:   0.01  - 99.99ug/kg/min (0.01ug/kg/min step)        0.01  - 99.99mg/kg/h (0.01mg/kg/h)
Body weight: 0.1  - 99.9 (0.1kg step); 100  - 300kg(1kg step)

Occlusion Pressure

High, Middle and low

Purge Rate(ml/h)

50ml (60ml): 1800.0ml/h, 20ml (30ml) 800.0ml/h, 10ml: 400.0ml/h  5ml: 200ml/h

Bolus Rage

10ml: 10-300ml/hr, 20ml(30ml): 0-600ml/hr, 50ml(60ml): 10-1200ml/hr

Bolus Volume

Maximum of 25ml

KVO Rate

1ml/h

Volume Limit Range

0.1-1999(0.1ml step)

Total Volume Range

0.1-1999(0.1ml step)

Accuracy

± 2% with correct calibration

Alarm

  Near empty, Syringe empty, Volume complete (when limit volume has been set), Occulusion, Syringe loose, Operation errors, Low battery and device failures.

Dimension(mm)

280mm(L)× 160mm(W)× 130mm(H)

Net weight(Kg)

2.2kgs

Power supply

AC power supply: AC 100 to 240V± 10%, 50/60Hz
Internal LI Battery: 11.1V, 2000mAh.   Approximmately 8 hours of continuous operation on a new and fully  charged battery running at 5ml/h.

 

 

 

Competitive Advantage:

 

Send message to this supplier
Mr. Frank wang chao
Tel: 86-311-68025728
Enter between 20 to 3,000 chatacters.
Contact Method
Hebei Aixuanda medical equipment Co.
1306-1314,zhongyuan building,huaian road, Shijiazhuang, Hebei, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!